Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
N4L PPA4530/4560/4510 Newton Power Analyzer

N4L PPA4530/4560/4510 Newton Power Analyzer

Model:PPA4530/4560/4510      Country of Origin:UK

Category:Power Analyzer

Overview:
UK N4L Newton PPA4500 Series PPA4510 PPA4520 PPA4530 High-Precision Power Analyzer is a three-channel power analyzer.
UK Newton N4L has focused on power analyzer research for over 30 years. The PPA5530 multi-channel high-precision power analyzer inherits its 30 years of research achievements and has created a huge sensation in the global power analyzer industry since its launch.
The PPA5530 three-channel high-precision power analyzer fundamentally solves the defect that traditional power analyzers cannot record test data in real time and truthfully. Making testing more realistic and more accurate is the direction that UK Newton N4L has always adhered to.
Measurable parameters: power, voltage, current, apparent power, reactive power, DC voltage, DC current, AC voltage, AC current, peak voltage, peak current, inrush current, power factor, frequency, phase, impedance, data processing, integration, fundamental wave, harmonics, distortion.


Features
Specifications
Application Notes
Functions & Configuration
  • 0.03%  basic test accuracy

  • BandwidthDC,10mHz to 2MHz

  • High-precision wideband built-in shunt

  • 1000Vrms - 3000Vpk  direct voltage input

  • Up to 50Arms - 1000Apkdirect current input

  • 5 millidegree  basic phase accuracy

  • 1, 2 or 3-phase versions

  • Master-slave configuration enables6-channel testing

  • All channels are fully independent and can perform high-speed sampling simultaneously

  • 1GB memory space

  • Easy to operate–single button provides direct access to all test modes

  • Real-time gapless test analysis

  • Real-time display in numeric, list, curve andoscilloscope formats

  • Real-time data logging and integration accumulation

  • SimpleBNC interface connectionfor high-current applications

  • RS232, USB, LAN,torque, speed and programmable interfaces, IEEE488(GPIB) optional

  • Rack-mount installation option

  • USB  external interface


3.jpg


2.jpg

Model

PPA4500

PPA5500

  Frequency range


DC,10mHz~2MHz -  PPA4500-LC(10Arms), PPA4500(30Arms)

DC,10mHz~2MHz -  PPA5500-LC(10Arms), PPA5500(30Arms)

DC,10mHz~1MHz - PPA4500-HC(50Arms)

DC,10mHz~1MHz - PPA5500-HC(50Arms)

Input voltage

Built-in

Range

1V~3000V peak (1000Vrms) within 8 ranges

300mVpk~3000Vpk(1000Vrms) in 9 ranges

(240Vrms within the 300V peak range, can withstand over 20% range)

(240Vrms within 300Vpk range, using 20% overange)

Accuracy

0.03% reading + 0.04% range + (0.004% × kHz reading) + 5mV

0.01% reading + 0.038% range + (0.004% × kHz reading) + 5mV

Impedance

1Mohm in parallel with 5pF, 90pF common mode to chassis

External

Range

1mV~3V peak within 9 ranges [BNC input *max 3V]

300μV peak within 9 ranges [BNC input *max 3V]

Accuracy

0.03% reading + 0.04% range + (0.004% × kHz reading) + 3μV

0.01% reading + 0.038% range + (0.004% × kHz reading) + 3μV

Impedance

3Mohm in parallel with 40pF, 90pF common mode to chassis

Input current

Built-in

10Arms low current

Range

10mApk~30Apk(10Arms) in 8Range

Range

3mApk~30Apk(10Arms) in 9Range

(PPA5500-LC)

Accuracy

0.03% reading + 0.04% range + (0.004% × kHz

Accuracy

0.01% reading + 0.038% range + (0.004% × kHz reading) + 30μA

4mm safety input

reading) + 30μA

30ArmsCurrent(PPA5500)

Range

100mApk~300Apk(30Arms) in 8Range

Range

30mApk~300Apk(30Arms) in 9Range

4mm safety input

Accuracy

0.03% reading + 0.04% range + (0.004% × kHz

Accuracy

0.01% reading + 0.038% range + (0.004% × kHz reading) + 300μA


reading) + 300μA

50Arms high current (PPA5500-HC) **

Range

300mApk~1000Apk(50Arms) in 8Range

Range

100mApk~1000Apk(50Arms) in 9Range

Accuracy

0.03% reading + 0.04% range + (0.004% × kHz

Accuracy

0.01% reading + 0.038% range + (0.004% × kHz reading) + 900μA

reading) + 900μA

External input (external current sensor)


Range

1mVpk~3Vpk in 8Range

Range

300μVpk~3Vpk in 9Range

BNC Connector (Max input 3Vpk)

Accuracy

0.03% reading + 0.04% range + (0.004% × kHz

Accuracy

See PPA5500-TE brochure for TE specification 0.01% reading + 0.038% range + (0.004% × kHz reading) + 3μV


reading) + 3μV

Phase accuracy


0.005deg+(0.01deg×kHz)【PPA45/5500-LC(10Arms), PPA45/5500(30Arms)】

0.01deg+(0.02deg×kHz)【PPA45/5500-HC(50Arms)】

Power accuracy

10mHz-2MHz

[0.04%+0.05%/pf+(0.01%×kHz)/pf] reading + 0.04% VA range

[0.03% + 0.03%/pf + (0.005% × kHz)/pf] reading + 0.03% VA range

40-850Hz

[0.03%+0.04%/pf+(0.01%×kHz)/pf] reading + 0.03% VA range

[0.02%+0.03%/pf+(0.005%×kHz)/pf] reading + 0.01% VA range

16-450Hz Low PF


See PPA5500-TE Brochure

Standard items

Crest factor

20 (voltage and current)

Sampling rate

2.2Ms/s across all ranges, gapless

IEC mode

IEC62301 standby power

IEC61000 harmonics and flicker, IEC62301 standby power

Application modes

PWM inverters, ballasts, inrush, power transformers, standby power

PWM Inverter, Ballast, Surge, Power Transformer, Standby Power, Pulse Harmonics, Flicker Meter, TVF105 Interharmonics

CMRR - Common Mode Rejection Ratio


250V @ 50Hz - ≥ 1mA (150dB)

100V @ 100kHz - ≥ 3mA (130dB)

Measurement parameters


W ,VA ,Var ,pf ,V & A - rms ,rectified mean ,AC ,DC ,Peak ,Surge ,Crest Factor ,Form Factor ,Star to Delta Voltage, +ve Pk, -ve Pk

Frequency (Hz), Phase (deg), Fundamentals, Impedance

Harmonics, THD, TIF, THF, TRD, TDD

Integrated Values, Datalog, Sum and Neutral values

Datalog - Up to 4 user selectable measurement functions (30 with optional PC software)

Data logging window

No-Gap analysis, Minimum window 10ms

No-Gap analysis, Minimum window 2ms

Storage

16,000 records

10M records into flash RAM (Non-Volatile)

Communication interface

RS232

Baud rate up to 38.4kbps,RTS/CTS flow control

LAN

(Option L) 10/100 Base-T Ethernet auto sensing

(Fitted as standard) 10/100 Base-T Ethernet auto sensing

GPIB

(Option G) IEEE488.2 Compatible

(Fitted as standard) IEEE488.2 Compatible

USB

USB 2.0 and 1.1 compatible

Analog output

Bipolar ±10V(BNC)

Speed input

BNC Bipolar±10V or Pulse count 1Hz to 1MHz 0.01% reading

Torque

BNC Bipolar±10V or Pulse count 1Hz to 1MHz 0.01% reading

Synchronized parallel operation

4–6 channel testing (master/slave)

Expansion

4~6 channels (master/slave) + auxiliary

Standard accessories

Cable

Power Cord, RS232, USB Cable

Power cord, RS232, USB, GPIB cables

Connection Cable

36A 1.5m long 4mm stackable terminals: 1x red, 1x yellow and 2x black per phase (1x red, 1x black with HC version)

Connecting plate

4mm terminated aligator clips - 1x red, 1x yellow and 2x black per phase (1x red and 1x black per phase with PPA5500-HC version)

CD-ROM

CommView2 (RS232/USB/LAN), Command line, Script based communication software

Manual documentation

User manual, Communications manual, Calibration certificate, Quick start guide

Physical parameters

Input impedance

Voltage attenuation and external input 1MΩ || 30pF

Display

320×240 color TFT, white LED backlight

Dimensions

130H×400W×315D mm excluding feet

Weight

5.4kg(1 Phase), 6kg(3 Phase)

Safety isolation

1000Vrms or DC(CATII), 600Vrms or DC(CATIII)

Operating power

90~265Vrms, 50~60Hz, 40VAmax

Operating Environment

23?0?8C ± 5?0?8C Ambient Temperature (or air intake temperature when rack mounted), 20-90% Non-Condensing Relative Humidity.

Temperature coefficient ±0.01% per ?0?8C of reading at 5-18?0?8C and 28-40?0?8C



undefined
  

Today's R&D engineers of power supplies, ballasts, motors and other equipment are facing market demands for product miniaturization and higher efficiency, which correspondingly drive the development of higher-frequency power conversion technologies and higher efficiency requirements, thereby increasing the demand for electrical parameter analyzers with wider frequency ranges and higher precision.

 

Based on market demand, Newton Technology has combined years of R&D experience in high-frequency test instruments and adopted innovative digital signal processing technology and analog hardware design technology to develop the *new generation PPA5500 series ultra-wideband high-precision power analyzer. Newton Technology's PPA5500 series not only adopts advanced design technology in R&D, but also makes the product more cost-effective, meeting the demand for high-precision power analyzers in almost all application scenarios.

 

Through 6 main function keys including POWER-INTEG-HARM-RMS-IMP-SCOPE, the PPA5500 series provides customers with great flexibility and convenience, allowing operators to easily select the required test mode. The result is that a single instrument can provide more and greater functional range and main measurement options than any competitor's product. By pressing any one of these buttons, the operator can immediately enter the required main measurement interface and directly obtain test data.