Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
N4L Power Analyzer PPA1510/PPA1510H/PPA1520/PPA1520HC/PPA1530/PPA1530HC Newton

N4L Power Analyzer PPA1510/PPA1510H/PPA1520/PPA1520HC/PPA1530/PPA1530HC Newton

Model:PPA1510/PPA1510H/PPA1520/PPA1520HC/PPA1530/PPA1530HC      Country of Origin:UK

Category:Power Analyzer

Overview:

Compact, cost-effective, mainstream specifications, British quality!




Features
Specifications
Application Notes
Functions & Configuration

The PPA1500 power analyzer outperforms its PPA500 series counterparts, ensuring that N4L power analyzers offer an optimal solution for virtually every power measurement application and budget.

The key difference between the PPA1500 and PPA500 power analyzers is that the PPA1500 features 1 MHz bandwidth and full graphical display, including harmonic bar charts and graphical data logging. The PPA1500 now incorporates a parallel digital filtering algorithm that enables its use in a wide range of pulse-width modulation applications. Despite being only half-rack width and 2U high, the PPA1500 can be configured with 1, 2, or 3 channels and delivers a level of performance typically found only in larger, more expensive instruments. The PPA1500 offers modes such as "inrush current" and "standby power" for fast, accurate, and convenient measurements in challenging environments.

The PPA1500 series power analyzers now offer a 6-channel 2U rack option, in which two PPA1530 units are mounted in the same rack. See our accessories page for more details.


1500.jpg



ISO 17025 calibration and verification


Every PPA1500 power analyzer supplied by N4L comes with a UKAS-accredited calibration certificate up to 850 Hz, as well as a UKAS-traceable calibration certificate up to 1 MHz. N4L has developed a number of custom power calibrators to verify the accuracy of each power analyzer across its entire frequency range—something very rare in the instrumentation industry. In addition, the development of an ISO 17025 (UKAS)-accredited closed-loop calorimeter in collaboration with the University of Oxford (UK) has validated the performance of N4L's custom power calibration platform with very low uncertainty, giving the market confidence in the wide-bandwidth performance of all N4L power analyzers.



● 0.05% basic accuracy with industry-leading high-frequency performance

● Bandwidth range: DC–10 mHz to 1 MHz.

● Built-in shunt—accepts any external shunt.

● 10 millidegree phase accuracy—essential for low power factor applications.

● 20 A (300 Apk) & 1000 Vrms (2500 Vpk) direct input, with support for a wider range of external sensors.

● Unique x10 gain mode for standby power measurement.

● 1 Ms/s high-speed sampling on all channels.

● Gap-free real-time analysis.

● Available with 1, 2, or 3 channels.

● High-contrast full-color graphical display with waveform and bar graph views.

● Simple BNC connection from N4L for high-current test applications.

● RS232, USB, and LAN standard; GPIB and auxiliary port expandable.


Frequency range


Bandwidth

DC, 10mHz ~ 1MHz

x10 DC, 10mHz ~ 100kHz

Input voltage


Direct input

Normal: 0-1000Vrms, 1Vpk ~ 2500Vpk (8 ranges = 1V, 3V, 10V, 30V, 100V, 300V, 1KV, 3KV)

x10 100mVpk ~ 300Vpk (8 ranges = 100mV, 300mV, 1V, 3V, 10V, 30V, 100V, 300V)

Direct input accuracy

Normal : 0.05% Rdg + 0.1% Rng + (0.005%xkHz) + 5mV

x10 : 0.05% Rdg + 0.1% Rng + (0.01%xkHz) + 1mV

External input (BNC)

1mVpk ~ 3Vpk [BNC Connector 3Vpk Max Input] 8 Ranges = 1mV, 3mV, 10mV, 30mV, 100mV, 300mV, 1V, 3V

External input accuracy

0.05% Rdg + 0.1% Rng + (0.005%xkHz) + 5uV

Input current


PPA1500 standard 20Arms direct input, 4mm safety jacks

Normal: 100mApk ~ 300Apk (20Arms) (8 ranges = 100mA, 300mA, 1A, 3A, 10A, 30A, 100A, 300A)

x10 : 10mApk ~ 300Apk (8 ranges = 10mA, 30mA, 100mA, 300mA, 1A, 3A, 10A, 30A)

PPA1500 standard 30Arms direct input, 4mm safety sockets

Normal: 300mApk ~ 1000Apk (30Arms) (8 ranges = 300mA, 1A, 3A, 10A, 30A, 100A, 300A, 1KA)

x10 : 30mApk ~ 100Apk (8 ranges = 30mA, 100mA, 300mA, 1A, 3A, 10A, 30A, 100A)

20Arms direct input accuracy

Normal : 0.05% Rdg + 0.1% Rng + 0.005%xkHz) + 500uA

x10 : 0.05% Rdg + 0.1% Rng + 0.01%xkHz) + 100uA

20Arms direct input accuracy

Normal : 0.05% Rdg + 0.1% Rng + 0.005%xkHz) + 1mA

x10 : 0.05% Rdg + 0.1% Rng + 0.01%xkHz) + 300uA

External sensor BNC current input

1mVpk ~ 3Vpk 8 Ranges = 1mV, 3mV, 10mV, 30mV, 100mV, 300mV, 1V, 3V

External sensor input accuracy

0.05% Rdg + 0.1% Rng + (0.005%/kHz) + 5uV

Phase accuracy


Normal

0.01deg + (0.01deg/kHz)

x10

0.01deg + (0.02deg/kHz)

Power accuracy


Normal

[0.1% + 0.1%/pf + (0.01%/kHz)/pf] Rdg + 0.1% VA Rng

x10

[0.1% + 0.1%/pf + (0.02%/kHz)/pf] Rdg + 0.1% VA Rng

40Hz ~ 850Hz

As above with range error reduced from +0.1% V,A,VA Rng to +0.05% V,A, VA Rng

Standard functions


Crest factor

20 (Voltage and Current)

Sampling rate

1Ms/s on all channels, real time No-Gap

IEC mode

IEC62301/EN50564 Standby Power Mode

Application modes

Ballast, Inrush, Standby Power

CMRR - Common Mode Rejection Ratio

250V @ 50Hz – ≥ 1mA (150dB) 100V @ 100kHz – ≥ 3mA (130dB)

Measurement parameters

W, VA, Var, pf, V & A – rms, rectified mean, AC, DC, peak, surge, crest factor, form factor, star to delta conversion, delta to star conversion


Frequency (Hz), Phase (deg), Fundamental, Impedance

Frequency (Hz), Phase (deg), Fundamentals, Impedance


Harmonics, THD, TIF, THF, TRD, TDD


Integrated Values, Datalog, Sum and Neutral Values

Data logging

(Up to 4 user selectable measurement functions (60 with PC software)

Record window

No-Gap analysis, Minimum Window 10ms

Storage

RAM up to 16,000 records

Communication interface

RS232, LAN, (Option L), USB, Extension (Aux)

Standard accessories


Cables

Power, RS232, USB

Test connection cables

20A (Std Version) or 30A (HC version) 1.5m long 4mm stackable terminals. 1x red, 1x yellow, 2x black per phase

Connecting plate

4mm terminated alligator clips – 1x red, 1x yellow and 2x black per phase

Manual

User manual, Communications manual

Other manuals and documents

Calibration certificate, Quick start guide

Physical parameters


Display

480×272 dot full colour TFT, White LED backlit

Dimensions

92H x 215W x 312D mm excluding feet

Weight

3.3kg (1 Phase), 4kg (3 Phase)

Safety isolation

1000Vrms or DC (CATII), 600Vrms or DC (CATIII)

Power supply

90 ~ 265Vrms, 50 ~ 60Hz, 40VA Max

Operating temperature

5 deg to 40 deg ambient temperature (or air intake temperature when rack mounted), 20-90% Non-condensing relative humidity.


PPA1500 options, software and accessories

COMMS_ICONCommunication interfaces:
  • Standard: LAN, USB and RS232 communication ports

  • Optional: GPIB communication port

PROBE_ICONProbe and probe accessory options:
  • UrukupUltra-low capacitance probe (active, for DUT probes susceptible to capacitive loading) – 1.5pF, 1000Vrms, DC to 2MHz, 1000:1

  • TT-HV 250High-voltage probe (passive) – 2.5kVpk, 100:1

  • TT-HVP 15HFHigh voltage probe – 15kVpk, 1000:1

  • ATT10– 10:1 attenuator (for cases where the voltage probe output does not meet the PPA external input 3Vpk maximum rating) – for connection to the PPA external input and external attenuating probes.

  • ATT20– 20:1 attenuator (for cases where the voltage probe output does not meet the PPA external input 3Vpk maximum rating) – for connection to the PPA external input and external attenuator probes.

EXTENSION_ICONExpansion port and accessory options:
  • PCIS– Phase-controlled inrush (used when the DUT source needs to be controlled relative to phase angle)

CONNECTOR_ICONLead, connection and interface options:
  • 20AOne-phase connection lead set (standard) – 20A, 1.5m long + crocodile clips

  • 36 ASingle-phase connection lead set – 36A rated current, 1.5m long + crocodile clips

  • Voltage breakout lead set – 3 x 2m BNC to BNC with 4mm banana voltage breakout + 2 x voltage low shorting leads (for use when the distance between analyzer and DUT is large and HF series external shunts are used, facilitating shorted voltage connections.

  • Universal breakout box – Single-phase 10Arms universal breakout box

  • RS232 cable (standard) – 9-pin null modem cable

  • USB cable (standard) – 2m long A male to B male USB cable

CASES_ICONCarrying case:
  • PPA5/15xx soft carrying case – black nylon padded case with accessory compartment, handle and strap

  • PPA5/15xx hard carrying caseCase – PPA5/15xx hard aluminum flight case with accessory compartment, handle and locks (ideal for aircraft racks)

RACK_ICONRack mount kit option:
  • PPA5/15xx Rack mounting kit (specify dual, left, center or right configuration) – 19" rack mounting kit for PPA5/15xx

CALIBRATION_ICONCalibration and documentation (new units standard with UKAS ISO17025 certificate):
  • Standard Recalibration(ISO17025 traceable) – Single-phase PPA (PPA1510)

  • Standard Recalibration(ISO17025 traceable) - Two-phase and three-phase PPA (PPA1520 and PPA1530)

  • ISO17025 UKAS Calibration + standard calibration – single-phase PPA (PPA1510)

  • ISO17025 UKAS Calibration + standard calibration – two-phase and three-phase PPA (PPA1520 and PPA1530)

  • PPA15xx loan instrument available during calibration or repair (available in Europe only)

  • Spare user manual – hard copy of user and communication manuals

CLAMP_ICONCurrent measurement options:
PC_ICONPC software (free):


Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)

Inquiry Type: Message