Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
IWATSU CS-8200 GaN/SiC semiconductor parameter analysis curve tracer, Iwatsu Japan

IWATSU CS-8200 GaN/SiC semiconductor parameter analysis curve tracer, Iwatsu Japan

Model:CS-8000      Country of Origin:Japan

Category:Semiconductor Parameter Analyzer

Overview:

Modular design with adjustable voltage up to 2 kV and optional current up to 2000 A; minimum current resolution better than 250 fA.

Features
Specifications
Application Notes
Functions & Configuration

CS-8000 Exterior

CS-8000 series


Key Specifications and Features of the CS-8000 Series

  • Maximum peak voltage 5 kV (constant voltage/DC pulse)

  • Maximum peak current 2,000 A (constant current/pulse)

  • High-resolution low-current measurement down to 250 fA (more than 4× that of previous models)

  • Extensive expandability (functions can also be added after purchase)
    Select according to voltage (200 V to 5 kV) and current (2 A to 2,000 A) measurement requirements.


  • Safe, effective measurement
    No need to reconnect cables for each measurement. (Configuration function included)


  • High-resolution large display
    12.1-inch TFT-LCD (1,280×800)



  • Remote control interface
    LAN connectivity. Full remote control of device settings. Integrates with probe stations via PC.



  • Intuitive user interface
    Function keys on the front panel and dedicated knobs for each function enable intuitive operation.


CS-8000 Series Model List


Main unit①*

HCunit②*

Test accessories③*

CS-8020

200V

2A

CS-205

50V

500A

CS-320MV

200V

2A

CS-8200

2kV

20mA

CS-210

50V

1,000A

CS-322HV/HC

5kV

2,000 A

CS-8500

5 kV

8 mA

S-220

50 V

2,000 A

CS-322HV/HC

5 kV

2,000 A

*Depending on the voltage and current of the device under test, select the HC unit ② and fixture ③ in addition to the main unit ①.


New productCS-8000 Semiconductor Curve Tracer


  • High-power testing up to 5kV and 2,000A

  • Accurate micro-current measurement (resolution 250fA)

  • Large 12.1-inch touchscreen

  • Flexible GATE signal output function

  • Extensive temperature characteristic measurement options

  • High-power on-wafer testing on the prober


The semiconductor curve tracer CS-8000 series is a combination of various modules, ideal for characteristic evaluation in all processes and supporting next-generation semiconductor measurement.
0.png                               1.png                      2.png


Main specifications

Gate voltage

Voltage range

Maximum measurement current

Current measurement resolution

±40v

0.2~5kV

2kA

250fA


During actual measurement
Benefits
  • Supports SiC and GaN devices

  • Also supports wafers and low-power devices

  • Also supports high-power devices

  • Supports minute current measurement


Easy-to-use user interface

Equipped with a high-definition large 12.1-inch TFT-LCD (1,280×800) display, in addition to touchscreen operation, intuitive operation is possible via function keys on the front panel and independent knobs for each function.
 

①X-Y display area


Any voltage/current parameters can be assigned to the X and Y axes, enabling display of various semiconductor characteristic curves such as Vds-Id characteristics, threshold voltage, and Vds-Vgs saturation characteristics. Multiple parameters can also be assigned to the Y axis. The scale can be switched between Log and linear.
 

②Y-T display area

The applied waveforms of measurements are displayed along a time axis like an oscilloscope. Since waveform anomalies such as oscillation at pulse-width measurement points can be checked in real time, it is easy to verify whether measurements were performed correctly. All applied waveform data can be saved together with the X-Y display data, allowing measurement results to be re-verified.

③Measurement data display area


Displays detailed measurement results, measurement conditions, and status in text form.
 

④Configuration setting area

Configure the measurement setup for the device. Graphical display assists with selection of voltage/current units and wiring changes.
 

⑤ Parameter setting area


In this area, measurement parameters and measurement limits are set, and manual/automatic measurement is switched.
 

⑥Operation panel

The front panel is equipped with buttons and rotary knobs, enabling simple manual measurement. The numeric keypad in the center allows input of parameter values. Manual measurement is easily performed using the drain/collector gate/base vertical-axis and horizontal-axis rotary knobs.
Output sources suited to the application

Voltage and current units required for measurement can be freely selected according to the application.


The photo on the right shows:

Upper: Test box

Lower section: High-current unit


■HV unit

This is a 2kV/5kV high-voltage unit. DC/pulse waves can be selected. Constant voltage and constant current drive measurement can be selected.

Main unit CS-8200 maximum voltage(maximum current)
2 kV( 20 mA )
Waveform DC, pulse Polarity positive/negative Measurement current resolution 250 fA


■MV unit (common to all main units)


This is a 200 V medium-voltage unit. Constant-voltage or constant-current drive measurement can be selected. In addition to DC and pulse, SIN, half-wave, and full-wave waveforms can also be selected.

Maximum voltage
(maximum current)

200 V (2 A)

Waveform

DC (200 mA),
Pulse (2 A),
SIN, half-wave, full-wave

Polarity

Positive/Negative/Bipolar

Measurement Current Resolution

250fA



■GATE unit (common to all main units)


This is a 40 V unit. Constant-voltage or constant-current drive measurement can be selected. In addition to DC and pulse, SIN can also be selected.



Maximum voltage (maximum current)

40 V (1 A)

Waveform

DC, pulse, sine wave

Polarity

Positive/Negative/Bipolar

Measurement Current Resolution

250fA



■HC Unit


Equipped with a high-current mode, supporting high-current measurement up to 2000 A. Pulse width, measurement period, and measurement range are variable.



HC Unit

CS-205

CS-210

CS-220

Maximum current
(Voltage)

500 A
( 50V)

1000A
( 50V)

2000A
( 50V)

Waveform

Pulse

Pulse width

10 microseconds to 1 millisecond

10 μs to 1000 μs

Polarity

Positive/Negative





Minimum current resolution 250 fA
By adopting a triaxial system and an optimized measurement system, leakage and noise within the equipment are reduced, enabling stable measurement of minute currents.
 



Versatile GATE signal output


GATE signals can be output and applied sequentially.


Hold time variable range

0.000 s to 5.000 s


Standby signal voltage range

Gate: -40 V to +40 V

 




Measurement of hysteresis

The CS-8000 features functions convenient for measuring wide-bandgap semiconductors such as SiC and GaN that exhibit hysteresis.


The dual-sweep function simultaneously displays UP sweep and DOWN sweep, allowing observation of hysteresis.

 



Safety structure

In addition to the interlock function, it also has an output limiting function.


Voltage, current, and power limit values can each be set, preventing damage to the DUT.

In addition, the hardware overcurrent protection function cuts off the current when it reaches 1.4 times the measurement range.

 


Configuration structure

HC units and fixtures can be selected according to the voltage and current of the measurement target.



■Configuration exampleWhen used at 2 kV, 2,000 A


Main unit

CS-8200 

Accessory power supply

HC Unit

CS-220

HV standard cable kit

Test box

CS-322

HC standard cable kit





CS-8000 series main specifications

Main unit model name

CS-8020

CS-8200

CS-8500(TBD )

 


HV unitHV unit

Maximum peak voltage (maximum current)


2000V(20mA)

5000V(8mA)

Measurement voltage range (full scale)


50 V to 2 kV

50 V to 5 kV

Measurement current range


50μAto 20mA

50μAto 20mA

Minimum measurement current resolution


250 fA

250fA

Waveform


DC/pulse

DC/pulse

 

MV unit

Maximum peak voltage (maximum current)

200 V (2 A)

Measurement voltage range (full scale)

200 mV ~ 200 V

Measurement current range

2 A to 5 A

Minimum measurement current resolution

250fA

Waveform

DC (200 mA), pulse (2 A), sine wave, half-wave, full-wave

 

Gate unit

Maximum peak voltage (maximum current)

40 V (1 A)

Measurement voltage range (full scale)

1 V to 50 V

Measurement current range

5 nA to 1 A

Minimum measurement current resolution

250fA

Waveform

DC pulse sine wave (50 Hz)

Standard accessories

Power cable, control interface terminator, instruction manual (booklet + CD)



HC unit model name

CS-205

CS-210

CS-215

Maximum peak current (maximum voltage)

500 A (50 V)

1000 A (50 V)

2000 A (50 V)

Measurement voltage range (full scale)

200 mV ~ 50 V

200 mV ~ 50 V

200 mV ~ 50 V

Measurement current range

500 mA to 500 A

500 mA to 1000 A

500 mA to 2000 A

Waveform

Pulse
(Width 10 μs ~ 1 ms )

Pulse
(Width 10 μs ~ 500 μs )

Pulse
(Width 10 μs~ 500 μs )

Standard accessories

Power cable, HC-FIXTURE connection unit, instruction manual

※When using the HC unit, a separate sensing cable is required.

 

Test fixture model name

CS-320MV (coming soon)

CS-322 HV/HC

Standard accessories

Power cable, standard wire kit (CS-005, 1 set of 7), instruction manual

――

HV/HC cable (2 cables)



※A separate cable is required when connecting a test fixture.

 

■Cable kit (used when connecting a test fixture or HC unit.)

Cable set name

Model

Product name

CS-020

MV standard cable set

(Recommended kit for CS-320)

CS-026

7 triaxial cables (L=1.0 m)

CS-027

1 control interface cable (L=1.0 m)

CS-028

1 interlock/readout cable (L=1.0 m)

CS-021

HV standard cable kit

(Recommended kit for CS-322)

CS-025

2 HV cables (L=1.0 m)

CS-026

7 triaxial cables (L=1.0 m)

CS-027

1 control interface cable (L=1.0 m)

CS-028

1 interlock/readout cable (L=1.0 m)

CS-022

HC standard cable kit

(Recommended kit for HC unit)

CS-026

1 control interface cable (L=1.0 m)

CS-028

1 interlock/readout cable (L=1.0 m)


Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)

Inquiry Type: Message