Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
NF ZM2371/2372/2376 Circuit Design 5.5MHz High-Frequency LCR Meter

NF ZM2371/2372/2376 Circuit Design 5.5MHz High-Frequency LCR Meter

Model:ZM2371/2372/2376      Country of Origin:Japan

Category:High-Frequency LCR Meter

Overview:

ZM2371

Basic accuracy 0.08%, frequency range 1mHz to 5.5MHz, measurement speed fastest 2ms, contact check, low capacitance check.

ZM2372

Basic accuracy 0.08%, frequency range 1mHz to 100kHz, measurement speed fastest 2ms, 4-terminal contact check function, handler interface.

ZM2376

Basic accuracy 0.08%, frequency range 1mHz to 5.5MHz, measurement speed fastest 2ms, contact check, low capacitance check.

Features
Specifications
Application Notes
Functions & Configuration

LCR Meter ZM2371/ZM2732/ZM2376


*
The NF LCR Meter ZM series covers measurement ranges from the low-frequency region of 1mHz to the high-frequency region of 5.5Hz, achieving fast and stable measurement with small deviation, and can be used for a variety of applications from material research to component production lines.

ZM2376
ZM2371_ZM2372




High reproducibility with small deviation - Measurement example


The results were obtained by repeatedly measuring a 1nF capacitor 200 times using the ZM2372 and ZM2376 under the following conditions.
With the ZM2376, measurement reproducibility is further improved.


ZM2376
● Measurement time: 5ms     
● 
Measurement frequency: 100kHz     
● 
Measurement signal level: 1V
ZM2372


Supports fast, high-precision, wide-range measurement


Wide frequency measurement range and high-resolution settings

ZM2371/ZM2372 cover the frequency range of 1mHz to 100kHz, and ZM2376 covers 1mHz to 5.5MHz. 5-digit/6-digit resolution can be set*, so in addition to measuring various components at their actual operating frequencies, the frequency dependence of parameters can also be evaluated.
*ZM2371/ZM2372: 5 digits, ZM2376: 6 digits


Wide-range measurement level and ALC function

The measurement signal level can be set with 3-digit resolution from 10 mVrms to 5 Vrms / 1 μArms to 200 mArms. In addition, the ALC (automatic level control) function enables constant-voltage/constant-current drive, allowing stable drive signals that account for the voltage/current dependence of the sample, achieving highly reproducible measurements.


Fast measurement

Measurement time can be switched among 5 levels: RAP (Rapid), FAST, MED (Medium), SLOW, and VSLO (Very Slow). Selecting RAP enables fast measurement of 2 ms (1 kHz/1 MHz) and 10 ms (120 Hz). A fast, high-precision LCR meter helps improve the measurement efficiency of production lines and automatic inspection equipment.


High precision

Achieves high-precision measurement with basic accuracy of 0.08% and display resolution of up to 6 digits. Reliable measurement is indispensable for improving product performance and quality, from cutting-edge device development to component sorting on inspection lines.


DC bias voltage

The ZM2371/ZM2372 include a built-in 0 to +2.5 V DC bias power supply, and the ZM2376 includes a built-in 0 to +5 V one, enabling measurement of polarized components such as electrolytic capacitors.
The ZM2376 can also quickly measure the impedance of lithium-ion batteries (single cells) and similar devices.
In addition, when using the optional DC voltage bias adapter*, it can be applied to the sample
±40V bias voltage, measuring the voltage dependence of large-capacity multilayer ceramic capacitors, etc.
*Options

zm_image
DC resistance (DCR) measurement

Can measure the DC resistance of the winding resistance of coils and transformers. Inductance can be displayed as the primary parameter and the DC resistance measurement value as the secondary parameter at the same time.



Line-oriented functions are also extensive!


Contact check function

● ZM2372

4-terminal contact check

To prevent erroneous measurement or incorrect sorting caused by poor contact between the measurement tip and components, the ZM2372 uses 4 measurement terminals to perform contact check judgment, thereby rejecting defective products.

(Additional time for contact check: 4 ms)

D[~24KJ5(}YUC1$J8M7ES@6.png

● ZM2376

Contact check, low capacitance check

Detects abnormal low capacitance, voltage, and current, and detects poor contact without additional time.


Trigger circuit synchronized drive

Enables driving the sample only during the contact period.
This reduces contact damage caused by attaching and detaching samples when measuring large-capacitance capacitors. When measuring samples with short measurement history characteristics, measurement values can show large errors. With trigger circuit synchronized drive, the drive signal applied to each sample and the timing and phase relationship of signal acquisition are fixed, suppressing measurement value errors and greatly shortening measurement time.


Deviation display

By presetting the displayed value of the measured component, the deviation and deviation % from the preset value can be displayed. This can be applied to pass/fail judgment against tolerance specification values of components and temperature characteristic tests, etc.


Comparator

Up to 14 BIN categories for the primary parameter*BIN categories; in the secondary parameter, measurement results can be sorted against one set of preset upper/lower limit values. Measured values can be sorted by deviation or deviation %, and judgment results are output via the handler interface*Output. In addition, depending on the judgment result, a beep sound may be emitted.
In remote control, using the limit judgment function, the upper and lower limit values (one set each) of the primary and secondary parameters can also be judged.
*ZM2371: Up to 9 classifications, not equipped with a handler interface.


Composite measurement (ZM 2376)

Composite measurement is a function that can specify measurement conditions for up to 32 steps for one sample and comprehensively perform pass/fail judgment. The measurement frequency, measurement signal level, internal DC bias, measurement parameters, etc. can be set for each step, and measurement and limit judgment are performed for one set of upper/lower limits for the primary parameter and one set for the secondary parameter.
*A function unique to the ZM2376.


+

Interface

+

Standard interfaces for remote control. Production line integration and automated inspection systems can be supported without additional options.


Interface

ZM2371

ZM2372

ZM2376

USB

○

○

○

RS-232

○

○

○

GPIB

-

○

○

LAN

-

-

○(Optional)

Handler

-

○

○


O1L$0NR1$DH8(0N2U{8GM~8.png
Built into component production lines and sorting equipment.
With a maximum speed of 2 ms, low-deviation measurement, a compensation function that suppresses the effects of the cables connecting the sample, a comparator, contact check*
and other functions, and also equipped with a handler interface for automatic sorting*, it is fully capable of meeting the needs of various production lines.
*Not equipped on ZM2371.




▲ Inductance measurement example (cable length 1 m, 2 m, 4 m)




Fast measurement of lithium-ion battery impedance.
The internal DC bias voltage of the ZM2376 can be set to a maximum of +5 V, so it can measure lithium-ion batteries (single cells) with an electromotive force exceeding 3 V.
In addition, measurement can start from a low frequency of 1 mHz, enabling detailed evaluation of the internal impedance of batteries.


Application software (standard)


+

Software that can set and acquire various measurement conditions and display measurement data is included as standard.
Measurement data can be obtained as CSV files, which is convenient for handling large amounts of data in research and development. In addition, sweep measurement supports impedance-frequency characteristic measurement.

Application software
Application software
Main settings screen
Chart display using Excel



● Operating environment

● OS: Windows 7 (32-bit/64-bit), Windows XP (32-bit), Windows Vista (32-bit)

● Interface: USB

Microsoft Excel 97 or later is required to save settings and measurement data in XLS format

Item

ZM2371

ZM2372

ZM2376

Measurement parameters

  Primary parameter: |Z|、|Y|、 L、 C、 R、 G
  Secondary parameter: Q、 D、 θ、 X、 B、 Rs、 Rp、 G、 Lp、 Rdc

Measurement frequency

1 mHz~100 kHz

1 mHz~5.5 MHz

Basic accuracy

0.08 %

Measurement signal level

10mVrms~5Vrms、1μArms~200mArms

InternalDCBias

0~+2.5V

0~+5V

Measurement time

1kHz

Fastest2ms

1MHz

—

—

Fastest2ms

Constant voltage/
Constant current drive (ALC)

○

○

○

Contact detection

—

○(4Terminal)

○

Low capacitance detection

—

—

○

Comparator

○(9Category)

○(14Category)

○(14Category)

Composite measurement

—

—

○(32steps)

Handler interface

—

○

○


Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)

Inquiry Type: Message