Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
Keithley 2510/2510-AT/2520 SourceMeter Optical Instrument Optical SMU TEKTRONIX USA

Keithley 2510/2510-AT/2520 SourceMeter Optical Instrument Optical SMU TEKTRONIX USA

Model:2510 /2510-AT/2520      Country of Origin:USA

Category:SMU Source Measure Unit

Overview:

Keithley instruments make it easy to build an LIV (light power-current-voltage) system for cost-effective testing of laser diode modules.

2520 Pulsed Laser Diode Test System: a synchronized test system that provides source and measurement capability for pulsed and continuous LIV testing.

TEC SourceMeter SMU, 2510 and 2510-AT: ensure tight temperature control of laser diode modules by controlling their thermoelectric coolers.


Features
Specifications
Application Notes
Functions & Configuration

image.png

Features

Benefits

Active temperature control

Prevents temperature fluctuations from shifting the laser diode's primary output wavelength, which can cause signal overlap and crosstalk.

50 W TEC controller

Delivers faster test speeds and a wider temperature setpoint range than lower-power solutions.

Fully digital P-I-D control

Delivers greater temperature stability and can be easily upgraded through a simple firmware change.

Auto-tuning for thermal control loops (2510-AT)

Determines the optimal combination of P, I, and D coefficients without trial and error.

Wide temperature setpoint range (–50°C to +225°C) with high setpoint resolution (±0.001°C) and stability (±0.005°C)

Meets the test requirements for production testing of most cooled optical components and subassemblies.

Compatible with multiple temperature sensor inputs — thermistors, RTDs, and IC sensors

Suited to the sensor types most commonly used in laser diode modules.

AC ohmic measurement

Verifies TEC device integrity.

Four-wire open/short lead detection for thermal feedback elements

Eliminates lead resistance errors and reduces the risk of false failures or equipment damage.


Model

Channel

Maximum current source/Range

Maximum voltage source/Range

Power supply

Measurement resolution (current/Voltage)

2510

1

5A

10V

50 W

-

2510-AT

1

5A

10V

50 W

-

2520

1

5A

10V

50 W

700nA / 0.33mV


Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)

Inquiry Type: Message