Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
Lianxun Instruments S2021H High-Precision Benchtop Source Measure Unit Four-Channel Precision Source/Measure Unit ±30 V, ±500 mA (DC, pulse)

Lianxun Instruments S2021H High-Precision Benchtop Source Measure Unit Four-Channel Precision Source/Measure Unit ±30 V, ±500 mA (DC, pulse)

Model:S2021H      Country of Origin:China

Category:SMU Source Measure Unit

Overview:

The Semight S2021H Precision Source/Measure Unit is a compact, cost-effective 4-channel benchtop source/measure unit (SMU) capable of sourcing and measuring voltage and current simultaneously. It delivers up to ±30 V and ±500 mA (DC/pulse) output, along with an excellent color LCD graphical user interface (GUI).

Features
Specifications
Application Notes
Functions & Configuration

Key Features

  • High Range

    Range: ±30 V, ±500 mA (DC and pulsed)
  • High Resolution

    Minimum measurement resolution down to 100 pA / 60 μV
  • High Sampling Rate

    ADC sampling rate up to 500 kS/s
  • Threshold triggering

    Hardware high-speed I/O enables threshold triggering for efficient interaction between measured outputs and the user's system



Features and benefits

  • I-V output capability


Voltage source specifications


Voltage setting accuracy

Range

Setting resolution

Accuracy (1 year)

±(% reading + offset) 【1】

Typical noise (RMS)

0.1 Hz-10 Hz

±30 V【3】

1 mV

0.03%+4 mV

1000 μV

±6 V

200 μV

0.03%+1 mV

100 μV

Temperature coefficient

±(0.15×accuracy specification)/℃ (0℃-18℃, 28℃-50℃)

Channel【2】

CH1-CH4

Output power

Maximum 3 W per channel, maximum 6 W total for four channels

Overshoot

<±0.1% (typical, Normal, step from 10% to 90% of range, full-scale point, resistive load test)

Noise

10Hz-20MHz

<3 mVrms, 6 V voltage source, 0.5 A resistive load

[1] Accuracy calculation example: to test the accuracy of a 1 V output on the 6 V range, the tolerance is:

[2] All channel outputs are electrically isolated from earth ground, but the outputs of CH1-CH4 share a common ground (LO), and the outputs of CH5-CH8 share a common ground (LO).

[3] This instrument outputs potentially hazardous high voltage (±31.5 V) to the HI/Sense HI/Guard terminals. To prevent electric shock, relevant safety precautions must be taken before power-on. Do not connect the Guard terminal to any output, including shorting it to chassis ground or output LO, otherwise the instrument will be damaged.



Current source specifications


Current accuracy

Range

Setting resolution

Accuracy (1 year)

±(% reading + offset)

Typical noise (RMS)

0.1Hz-10Hz

±500 mA【4】

20 μA

0.05% + 100 μA + Vo*25 μA

10 μA

±100 mA

4 μA

0.05% + 10 μA+ Vo*5 μA

1 μA

±10 mA

400 nA

0.05% + 5 μA + Vo*500 nA

100 nA

±1 mA

40 nA

0.05% + 500 nA + Vo*50 nA

10 nA

±100 μA

4 nA

0.05% + 50 nA + Vo*5 nA

1 nA

±10 μA

400 pA

0.05% + 20 nA + Vo*500 pA

150 pA

Temperature coefficient

±(0.15×accuracy specification)/℃ (0℃-18℃, 28℃-50℃)

Channel【5】

CH1-CH4

Output power

Maximum 3 W per channel, maximum 6 W total for four channels

Overshoot

<±0.1% (typical, Normal, step from 10% to 90% of range, full-scale point, resistive load test)

[4] The 500 mA range supports the 6 V voltage range only.

[5] All channel outputs are electrically isolated from earth ground, but CH1-CH4 channel outputs share a common ground (LO), and CH5-CH8 channel outputs share a common ground (LO)



Voltmeter specifications


Voltmeter accuracy

Range

Measurement resolution

Accuracy (1 year)

±(% voltage + offset)

±30 V

300 μV

0.03%+4 mV

±6 V

60 μV

0.03%+1 mV

Temperature coefficient

±(0.15×accuracy specification)/℃ (0℃-18℃, 28℃-50℃)



Ammeter specifications


Ammeter accuracy

Range

Measurement resolution

Accuracy (1 year)

±(% current + offset)

±500 mA【6】

10 μA

0.05% + 100 μA + Vo*25 μA

±100 mA

1 μA

0.05% + 10 μA+ Vo*5 μA

±10 mA

100 nA

0.05% + 5 μA + Vo*500 nA

±1 mA

10 nA

0.05% + 500 nA + Vo*50 nA

±100μA

1 nA

0.05% + 50 nA + Vo*5 nA

±10μA

100 pA

0.05% + 20 nA + Vo*500 pA

Temperature coefficient

±(0.15×accuracy specification)/℃ (0℃-18℃, 28℃-50℃)

[6] The 500 mA range supports the 6 V voltage range only.