Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
Lianxun Instruments S2024H High-Precision Benchtop Source Measure Unit 24-Channel Precision Source/Measure Unit ±4.5 V, ±10 mA (DC, pulse)

Lianxun Instruments S2024H High-Precision Benchtop Source Measure Unit 24-Channel Precision Source/Measure Unit ±4.5 V, ±10 mA (DC, pulse)

Model:S2024H      Country of Origin:China

Category:SMU Source Measure Unit

Overview:

The Semight S2024H Precision Source/Measure Unit is a compact, cost-effective 24-channel benchtop source/measure unit (SMU) capable of sourcing and measuring voltage and current simultaneously, delivering up to ±4.5 V and ±10 mA (DC/pulse) output with an excellent color LCD graphical user interface (GUI).

Features
Specifications
Application Notes
Functions & Configuration

Key Features

  • High Range

    Range: ±4.5 V, ±10 mA (DC and pulsed)
  • High Resolution

    Minimum measurement resolution down to 10 pA / 1 μV
  • High Sampling Rate

    Supports ADC sampling rates up to 1 MSa/s
  • Threshold triggering

    Hardware high-speed I/O enables threshold triggering, allowing efficient interaction between measurement outputs and the user's system




Voltage specifications  

Voltage accuracy

Range【1】

Setting resolution

Accuracy (1 year) 【2】

±(% reading + offset)

Typical noise (RMS)

0.1 Hz-10 Hz

±4.5 V

1 μV

0.02% +100 μV

5 μV

Temperature coefficient

±(0.15×accuracy specification)/℃ (0℃-18℃, 28℃-50℃)

Channel【3】

CH1 to CH24

Overshoot

<±0.1% (typical, Normal, step from 10% to 90% of range, full-scale point, resistive load test)

Noise

10Hz-20MHz

<3 mVrms, 4.5 V voltage source, 10 mA resistive load

[1] Do not connect the Guard terminal to any output, including shorting it to chassis ground or output LO, otherwise the instrument will be damaged

[2] Accuracy calculation example: when testing the accuracy of a 1V output on the 4.5V range, the tolerance is:

[3] All channel outputs are electrically isolated from earth ground, but CH1-CH12 channel outputs share a common ground (LO), and CH13-CH24 channel outputs share a common ground (LO).


Current specifications

Current accuracy

Range

Setting resolution

Accuracy (1 year)

±(% reading + offset)

Typical noise (RMS)

0.1Hz-10Hz

±10 mA

10 nA

0.05% + 5 μA

20 nA

±1 mA

1 nA

0.05% + 500 nA

10 nA

±100 μA

100 pA

0.05% + 50 nA

200 pA

±10 μA

10 pA

0.05% + 5 nA

100 pA

Temperature coefficient

±(0.15×accuracy specification)/℃ (0℃-18℃, 28℃-50℃)

Channel【4】

CH1 to CH24

Overshoot

<±0.1% (typical, Normal, step from 10% to 90% of range, full-scale point, resistive load test)

[4] All channel outputs are electrically isolated from earth ground, but CH1-CH12 channel outputs share a common ground (LO), and CH13-CH24 channel outputs share a common ground (LO)