Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
Lianxun Instruments S2011C Single-Channel PXIe Plug-in Source Measure Unit Precision Power/Measurement Unit ±60 V, ±3 A (DC), ±10 A (pulse)

Lianxun Instruments S2011C Single-Channel PXIe Plug-in Source Measure Unit Precision Power/Measurement Unit ±60 V, ±3 A (DC), ±10 A (pulse)

Model:S2011C      Country of Origin:China

Category:SMU Source Measure Unit

Overview:

A cost-effective single-channel PXIe source/measure unit that supports PXIe chassis from major vendors and multi-card synchronization. It can be integrated into production test systems to improve test throughput and reduce costs, and it supports Adaptive PFC.

Features
Specifications
Application Notes
Functions & Configuration

Features

  • High transfer rate

    Single-channel standard PXIe precision power supply
  • High range

    ±60 V, ±3 A (DC), ±10 A (pulse)
  • High resolution

    Minimum measurement resolution down to 100 fA / 100 nV
  • Easy to expand

    Fits standard PXIe chassis for effortless multi-channel expansion

Features and benefits

  • 5 functions in one

    Voltage source
    Current source
    Ammeter
    Voltmeter
    Electronic load
  • Quadrants I and III operate as a source: the actual polarity of the V/I output follows the source setting;
    Quadrants II and IV operate as a load: CC and CV work together; when used as a load, the load setting polarity is opposite to the source polarity;
  • Capable of testing a wide range of devices

  • Capture more measurement data

    ♦ 6.5-digit resolution: accuracy comparable to a 6.5-digit multimeter;
    ♦ 100 fA / 100 nV resolution: exceptional sensitivity for both sourcing and measurement;
    ♦ 1M points/s: high-speed measurement with fast setup and digitizing rates for arbitrary waveform generators and list sweeps;
  • Extensive sweep capabilities

  • DC I-V output capability

  • Pulsed I-V output capability


Voltage specifications




Voltage accuracy

RangeSetting resolutionAccuracy (1 year) ±(% reading + offset)1Typical noise (RMS) 0.1 Hz-10 Hz
±60 V210 μV0.02%+3 mV200 μV
±6 V1 μV0.02%+0.3 mV60 μV
±0.6 V100 nV0.02%+50 μV20 μV
Temperature coefficient±(0.15 × accuracy specification)/°C (0℃-18℃, 28℃-50℃)
settling time

<50 μs (typical)

Overshoot<±0.1% (typical, Normal, step is 10% to 90% of range, full-scale point, resistive load test)
Noise 10Hz-20MHz

6 V voltage source, 3 A resistive load, <5 mVrms


[1] Accuracy calculation example: to test the accuracy of a 120 mV output on the 600 mV range, the tolerance is:

[2] This instrument has potentially hazardous high voltage (±63 V) output to the HI/Sense HI/Guard terminals. To prevent electric shock, relevant safety precautions must be taken before powering on. Do not connect the Guard terminal to any output, including shorting it to chassis ground or output LO, otherwise the instrument will be damaged


Current specifications










Current accuracy

RangeSetting resolutionAccuracy (1 year) ±(% reading + offset)Typical noise (RMS) 0.1 Hz-10 Hz
±10 A3


1 μA


0.03% + 2mA


20 μA

±3 A
±1 A100 nA0.03% + 90 μA3 μA
±100 mA10 nA0.03% + 9 μA200 nA
±10 mA1 nA0.03% + 900 nA20 nA
±1 mA100 pA0.03% + 90 nA2 nA
±100 μA10 pA0.03% + 9 nA200 pA
±10 μA1 pA0.03% +1 nA30 pA
±1 μA4100 fA0.03% + 200 pA5 pA
Temperature coefficient±(0.15 × accuracy specification)/°C (0℃-18℃, 28℃-50℃)
settling time<100 μs (typical) 
Overshoot<±0.1% (typical, Normal, step is 10% to 90% of range, full-scale point, resistive load test)


[3] The 10 A range supports pulse mode only; accuracy is typical

[4] For low-current measurement, triaxial cable connection is recommended: Hi to the center conductor, Guard to the inner shield, outer shield to protective ground; LO to the center conductor, inner shield unconnected, outer shield to protective ground. The rated insulation voltage of the coaxial cable shall be no less than 250 V


Minimum programmable pulse width100 μs
Pulse width programming resolution1 μs
Pulse width programming accuracy±10 μs
Pulse width jitter2 μs
Pulse width definitionAs shown in the figure below, the time from the 10% leading edge to the 90% trailing edge





Pulse specificationsMaximum current limitMaximum pulse widthMaximum duty cycle
10.4 A/50 VDC, unlimited100%
21 A/20 VDC, unlimited100%
33 A/6.6 VDC, unlimited100%
410 A/20 V1 ms5%
510 A/50 V400 μs2%