Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
Lianxun Instruments S2016C Single-Channel PXIe Plug-in Source Measure Unit Precision Power/Measurement Unit ±200 V, ±1 A (DC), ±3 A (pulse)

Lianxun Instruments S2016C Single-Channel PXIe Plug-in Source Measure Unit Precision Power/Measurement Unit ±200 V, ±1 A (DC), ±3 A (pulse)

Model:S2016C      Country of Origin:China

Category:SMU Source Measure Unit

Overview:

Lianxun Instruments S2016C  A compact, cost-effective single-channel PXIe source/measure unit (SMU) that simultaneously sources and measures voltage and current. It delivers up to ±200 V, ±1 A (DC), ±3 A (pulsed), and 20 W of constant power, supports standard SMU SCPI commands for quick and easy migration of existing test code, and is compatible with PXIe chassis from major vendors. Multi-card synchronization is supported, enabling integration into production test systems to boost throughput and reduce cost.

Features
Specifications
Application Notes
Functions & Configuration

Features

  • High precision

    Resolution down to 1 fA / 100 nV

  • High range, high-speed measurement

    ±200 V, ±1 A (DC),
    ±3 A (pulse);
    sampling rates up to 1 MS/s

  • Adaptive PFC system

    With the Adaptive PFC
    (Precise-Fast Control) system,
    users can adjust parameters according to load characteristics

  • Building a Single-Channel Test System

    Based on a standard PXIe chassis for easy expansion

Features and Benefits

  • 5 functions in one

    Voltage source
    Current source
    Ammeter
    Voltmeter
    Electronic load

  • Quadrants I and III operate as a source: the actual polarity of the V/I output follows the source setting;
    Quadrants II and IV operate as a load: CC and CV work together; when used as a load, the load setting polarity is opposite to the source polarity;

  • Test a wide range of devices

  • Capture more measurement data

    ♦ 6½-digit resolution: accuracy comparable to a 6½-digit digital multimeter;
    ♦ 1 fA / 100 nV resolution: excellent sensitivity for both sourcing and measurement;
    ♦ 1 M points/s: high-speed measurement with fast setup and digitizing rates for arbitrary waveform generation and list sweeps;

  • Extensive sweep capabilities


Voltage specifications  

Voltage accuracy

Range

Measurement resolution

Accuracy (1 year)

±(% reading + offset)1

Typical noise (RMS)

0.1 Hz-10 Hz

±200 V2

100 μV

0.03%+10 mV

400 μV

±40 V

10 μV

0.03%+2 mV

100 μV

±20V

10 μV

0.03%+1 mV

50 μV

±2 V

1 μV

0.03%+100 μV

10 μV

±0.6 V

100 nV

0.03%+50 μV

2 μV

Temperature coefficient

±(0.15 × accuracy specification)/℃ (0℃-18℃, 28℃-50℃)



Overshoot

<±0.1% (typical, Normal, step is 10% to 90% of range, full-scale point, resistive load test)

Noise 10Hz-20MHz

20 V voltage source, 1 A resistive load, <5 mVrms

Current specifications

Current accuracy

Range

Measurement resolution

Accuracy (1 year)

±(% reading + offset)

Typical noise (RMS)

0.1 Hz-10 Hz

±3 A1

1 μA

0.03% + 2mA

20 μA

±1 A

100 nA

0.03% + 90 μA

4 μA

±100 mA

10 nA

0.03% + 9 μA

600 nA

±10 mA

1 nA

0.03% + 900 nA

60 nA

±1 mA

100 pA

0.03% + 90 nA

6 nA

±100 μA

10 pA

0.03% + 9 nA

700 pA

±1 μA2

100 fA

0.03% + 200 pA

20 pA

±10 nA23

10 fA

0.06% +9 pA

600 fA

±1 nA23

1 fA

0.1% +3 pA

60 fA

±100 pA23

1 fA

0.3% +1 pA

30 fA

Temperature coefficient

±(0.15 × accuracy specification)/℃ (0℃-18℃, 28℃-50℃)



Overshoot

<±0.1% (typical, Normal, step is 10% to 90% of range, full-scale point, resistive load test)

1. The 3 A range supports pulse mode only; accuracy is typical

2. For weak low-current measurements, it is recommended to keep using triaxial cable connections. If a triaxial terminal is used to convert to ordinary wiring output, the current accuracy of the instrument will be affected

3. Additional specification conditions: NPLC configured to 10 PLC


Pulse source specifications (4-wire)

Minimum programmable pulse width

100 μs

Pulse width programming resolution

1 μs

Pulse width programming accuracy

±10 μs

Pulse width jitter

2 μs

Pulse width definition

As shown in the figure below, the time from the 10% leading edge to the 90% trailing edge

  


Pulse specifications

Maximum current limit

Maximum pulse width

Maximum duty cycle

1

0.1 A/200 V

DC, unlimited

100%

2

1 A/20 V

DC, unlimited

100%

3

3 A/66.6 V

1 ms

5%

4

3 A/160 V

400 μs

2%


Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!