Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
Lianxun Instruments S2019C Four-Channel PXIe Plug-in Source Measure Unit Precision Power/Measurement Unit ±40 V, ±500 mA (DC), ±1 A (pulse)

Lianxun Instruments S2019C Four-Channel PXIe Plug-in Source Measure Unit Precision Power/Measurement Unit ±40 V, ±500 mA (DC), ±1 A (pulse)

Model:S2019C      Country of Origin:China

Category:SMU Source Measure Unit

Overview:

Semight Instruments S2019C A compact, cost-effective four-channel PXIe source/measure unit (SMU) that simultaneously sources and measures voltage and current, delivering up to ±40 V and ±500 mA (DC) or ±1 A (pulsed). It supports standard SCPI commands for fast, easy migration of test code, is compatible with mainstream PXIe chassis, and supports multi-card synchronization for integration into production test systems, improving test throughput and reducing cost.

Features
Specifications
Application Notes
Functions & Configuration

Key Features

  • Easy to expand

    4-channel standard PXIe precision power supply, easily scalable
  • Wide range

    Ranges: ±40 V, ±500 mA (DC), ±1 A (pulsed)
  • High resolution

    Minimum measurement resolution down to 1 pA / 1 μV
  • High sampling rate

    Supports ADC sampling rates up to 1 MS/s

Features and benefits

  • 5 functions in one

    Voltage source
    Current source
    Ammeter
    Voltmeter
    Electronic load
  • Quadrants I and III operate as a source: the actual polarity of the V/I output follows the source setting;
    Quadrants II and IV operate as a load: CC and CV work together; when used as a load, the load setting polarity is opposite to the source polarity;
  • Capable of testing a wide range of devices

  • Capture more measurement data

    ♦ 6-digit resolution: accuracy comparable to a 6½-digit DMM;
    ♦ 1 pA / 1 µV resolution: excellent measurement sensitivity;
    ♦ 1 MS/s ADC sampling rate: enables high-speed measurement, with fast setup and digitization rates for the arbitrary waveform generator (list sweep);
  • Extensive sweep capabilities


Voltage specifications

Voltage accuracy

Range

Resolution

Accuracy (1 year)

±(% reading + offset) 【1】

Typical noise (RMS)

0.1 Hz-10 Hz

±40 V

10μV

0.015%+1.2 mV

20 μV

±6 V

1 μV

0.015%+600 μV

6 μV

Temperature coefficient

±(0.15×accuracy specification)/℃ (0℃-18℃, 28℃-50℃)

Channel【2】【3】

CH0 to CH3

Output power

Max. 4 W per channel, max. 8 W total for four channels

Overshoot

<±0.1% (typical, Normal, step from 10% to 90% of range, full-scale point, resistive load test)

Noise

10Hz-20MHz

6 V voltage source, 0.5 A resistive load, <3 mVrms

[1] Accuracy calculation example: To test the accuracy of a 1 V output on the 6 V range, the tolerance is:

[2] All channel outputs are electrically isolated from earth ground, but the outputs of all channels share a common ground (LO)

[3] This instrument has potentially hazardous high voltage (±42 V) output to the HI/Sense HI/Guard terminals. To prevent electric shock, relevant safety precautions must be taken before power-on. Do not connect the Guard terminal to any output (including shorting to chassis ground or output LO), otherwise the instrument will be damaged



Current specifications

Current accuracy

Range

Resolution

Accuracy (1 year)

±(% reading + offset)

Typical noise (RMS)

0.1Hz-10Hz

±1 A【4】【5】

500 nA

0.1% + 125 μA

3μA

±500 mA【5】

±100 mA

100 nA

0.03% + 25 μA

500 nA

±10 mA

10 nA

0.03% + 2.5 μA

50 nA

±1 mA

1 nA

0.03% + 250 nA

5 nA

±100 μA

100 pA

0.03% + 25 nA

500 pA

±10 μA

10 pA

0.03% + 3 nA

100 pA

±1 μA

1 pA

0.03% + 500 pA

30 pA

Temperature coefficient

±(0.15×accuracy specification)/℃ (0℃-18℃, 28℃-50℃)

Channel

CH0 to CH3

Output power

Max. 4 W per channel, max. 8 W total for four channels

Overshoot

<±0.1% (typical, Normal, step from 10% to 90% of range, full-scale point, resistive load test)

[1] The 1 A range supports pulse mode only; accuracy is typical

[2] The 1A and 500mA ranges support only the 6V voltage range