Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
IWATSU SY-8218/SY-8219 B-H Analyzer - DC-bias +POWER LOSS test system

IWATSU SY-8218/SY-8219 B-H Analyzer - DC-bias +POWER LOSS test system

Model:SY-960      Country of Origin:Japan

Category:B-H Analyzer

Overview:

With up to 30 A DC bias capability, paired with the SY-8218 BH analyzer system, it enables the industry's widest AC/DC superposition application range and reproduces power inductor application conditions with maximum fidelity.

Features
Specifications
Application Notes
Functions & Configuration
Easily and accurately measure DC bias characteristics automatically, such as for power inductors

DC bias tester
SMD power inductor toroidal coil
  • Maximum DC bias: 30 A

  • Max ripple: ±6A

  • Measurement frequency (sine wave):
    10 kHz to 3 MHz

  • Measurement frequency (square wave):
    10 kHz to 1 MHz (10%-90% Duty)

DC bias non-sinusoidal wave
Square wave (current through the sample is triangular = simulated chopper), superimposing DC on a sine wave to measure magnetic characteristics

Measurement example of chip inductor (chopper excitation)
Measurement example of chip inductor (chopper excitation)
Automatic test on power inductor properties with DC biasing

DC-bias test system SY-960, SY-961, SY-962
DC-bias test system SY-960, SY-961, SY-962

SMD Power inductorToroidal coil inductor
  • DC bias current: 30A, max

  • AC Ripple current: ±6A, max

  • Test frequency(Sinusoidal): 10kHz to 3MHz

  • Test frequency(Pulse): 10kHz to 1MHz (Duty10%-90%)

DC biasing non-sinusoidal signalPulse(Triangular signal waveform in current at specimen, called QUASI-CHOPPER), or Sinusoidal test with DC biasing

DC Bias Tester SY-960 Specifications
ItemsSpecifications
Measurement FrequencySINE10kHz to 3MHz (with SY-8218), 10kHz to 1MHz (with SY-8219)
PULSE10kHz to 1MHz (Duty 10 to 90%)
Measurement Temp.0ºC to +250ºC
Max. Input Current±6A
Max. Input Voltage±200V
Performance Guarantee Temp.+18ºC to +28ºC
Operation HumidityLess than 85%RH (+35ºC, No Condensation)
Warm up TimeAccuracy of current is the guaranteed value after the 30 minutes warm-up time.
Dimensions (mm)330(W) x 320(D) x 200(H) Excluding projection
WeightApprox. 6.7kg
AccessoryDCT Cable (SY-963) x 1, PCB1528-030 x 1, PCB5650-079 x 1
Thumbscrew for the terminal block: x 2, Blower brush x 1, Accessory Case x 1
Instruction Manual CD x 1, User's Guide (A4 size) x 1
ItemsSpecificationsPower SupplyAC100V to 240VPower ConsumptionMax. 640VA (with SY-962)Current ldcDC 0.00 to 30.0ACurrent Resolution0.01ACompliance VoltageMax. 10V (between H-L)Performance Guarantee Temp.+18ºC to +28ºCOperation HumidityLess than 85%RH(+35ºC, No Condensation)Dimensions (mm)420(W) x 480(D) x 221(H) Excld. projectionWeightApprox. 15.3kgAccessoryPower Code x 1, Code x 1ItemsSpecificationsPower SupplyDC24V(Supplied from SY-961)InductanceApprox. 1.68[mH]±15% (between H-L)Max. Input Current30.0APerformance Guarantee Temp.+18ºC to +28ºCDimensions (mm)420(W) x 80(D) x 110(H)Excld. projectionWeightApprox. 14.0kgAccessoryJoint Fittings x 4ACB Cable L x 1ACB Cable S x 1DC Cable L Red/Black x 1eachDC Cable S Red/Black x 1each


-[eys

In actual circuits, DC magnetic fields and AC magnetic fields are usually applied to magnetic components, so measuring magnetic characteristics under varying DC bias is very important.




Measurement unit

ferrite

L=1.0μH

Graph


Graph

Measurement unit

Fe-Based amorphous

L=311μH



Graph

Measurement unit

iron powder

L=8.4μH

Graph


Graph

* The DC bias tester is a dedicated option for the SY-8218 and SY-8219 and cannot be used with other devices.
• Adjustment with the B-H analyzer main unit is required at the factory.
* If you already own the main unit (SY-8218/8219), replacement and adjustment must be performed at our factory.

DC-bias test system is uniquely used as an option for SY-8218 or SY-8219 and not be used with other equipment. Adjustment and inspection as a system with BH analyzer is requited.
BH analyzers(SY-8218/SY-8219) at the customer end will be returned to our factory for adjustment and inspection when DC-bias test system can be configured as a system.


Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)

Inquiry Type: Message