Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
IWATSU SY-8218\SY-8219 IWATSU Soft Magnetic AC B-H Core Loss POWER LOSS Analyzer

IWATSU SY-8218\SY-8219 IWATSU Soft Magnetic AC B-H Core Loss POWER LOSS Analyzer

Model:SY-8219/SY-8218       Country of Origin:Japan

Category:B-H Analyzer

Overview:

For magnetic characteristics, flux density B (in T) and magnetic field strength H (in A/m) are plotted on the conventional X-Y axes, and the resulting curve is called the B-H curve. Methods for measuring the B-H curve include DC and AC evaluation methods. Our company currently offers a continuous AC measurement method for testing the B-H curve of magnetic materials under AC conditions. This capability has been well received by many users. Accordingly, today's AC B-H curve tracer is defined as a "B-H analyzer."

Features
Specifications
Application Notes
Functions & Configuration

B-HFeatures of the SY-8218 Analyzer


bh_49.jpg



Two cursors—a crosshair and a slanted cursor—display measured values and permeability at any point. In addition to the standard crosshair, the slanted cursor was optimized based on customer feedback specifically for measuring permeability at any point on the B-H curve, making testing more convenient.
1. Stable, high-precision measurement
With a standard calibration resistor, even materials with extremely low core loss, such as dust cores, can be measured stably and with high precision.
 
2. Captured waveform data at 8192 points per cycle
This product captures waveform data at 8192 points per cycle—16 times more than our previous models—enabling high-precision measurement of coercive force, residual magnetic flux density, and other parameters.
 
3. Pulse excitation included as standard
Pulse excitation (up to 1 MHz, 50% duty cycle) can be added to sine-wave excitation as standard equipment.
 
4. Parameter comparison setup
B-H curves of the same product measured under different conditions can be compared.
 
5. Two cursor types



Measurement method

CROSS-POWER method (per IEC62044-3)

Measurement mode

B-H measurement, Pc measurement, µ measurement

Measurement items (characteristic values)

B-H measurement:

--Magnetic flux density (Bm), residual magnetic flux density (Br), --Magnetic field (Hm), coercive force (Hc), squareness ratio (Br/Bm), amplitude permeability (ua), iron loss (Pc, Pcv, Pcm), current-voltage phase difference (q), total flux change (2Φm)


Pc measurement:

--Magnetic flux density (Bm), residual magnetic flux density (Br), --Magnetic field (Hm), coercive force (Hc), amplitude permeability (ua), iron loss (Pc, Pcv, Pcm), current-voltage phase difference (q), apparent power (VA)


u measurement:

--Magnetic flux density (Bm), --Magnetic field (Hm), impedance permeability (uZ), complex permeability (m', m''), amplitude permeability (ua), iron loss (Pc, Pcv, Pcm), current-voltage phase difference (q), dissipation factor (tanδ), inductance (L), resistance(R), impedance (Z), quality factor (Q)

Saturation magnetic flux density (Bs), coercivity (Hc), residual magnetic flux density (Br), squareness ratio (Br/Bm), core loss (Pc, Pcv, Pcm), amplitude permeability (ua), phase adjustment (q), AC initial permeability (uiac), inductance (L), Q value (Q), [unit system: SI unit system]

Waveform

B-H curve, waveforms of excitation current / induced voltage / magnetic field / magnetic flux density

Measurement frequency

10 Hz to 10 MHz (with option: 1 Hz)

Magnetic field signal detection

Voltage drop method across non-inductive resistor   -- signal-derived current ±6A

Magnetic flux density signal detection

Induced voltage detection; coil terminal voltage detection method  -- signal detection voltage ±200 V

Digital resolution

16-bit resolution (8192 points/cycle)

Specimen connection type

2-winding method (excitation winding, output winding) and 1-winding method (excitation and output windings shared)

Display type

Color LCD display (800*600 dot)

Power supply

100 V to 240 V 50/60 Hz, power consumption approx. 130 VA MAX

Dimensions and weight

Approx. 12.5 kg, 420 W × 266 H × 480 L, each ±2 mm (excluding protrusions)

Interface

USB (data storage)


3c0d642a-c223-4f2d-8593-aae60dc05607

Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)

Inquiry Type: Message