Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
Krohn-Hite Precision DC SOURCE 523 DC power supply, calibrator

Krohn-Hite Precision DC SOURCE 523 DC power supply, calibrator

Model:523      Country of Origin:USA

Category:Precision Low-Noise DC Power Supply

Overview:

7.5-digit ultra-high precision and ultra-high stability of one part per million.

Features
Specifications
Application Notes
Functions & Configuration

●DC voltage and DC current
●Stability: ±1ppm
●Resolution: 7½ Digits
●Maximum output current: 110mA
● 2-wire and 4-wire output
●Optional output voltage range: 17V - 100V
●Auto Zero Offset Calibration (AZOC)
●Automatic "Covers On" calibration


The Krohn-Hite Model 523 precision DC power supply is a highly stable and repeatable DC voltage source and DC current source, providing N.I.S.T. traceable voltage and current for production, calibration laboratories, QA and QC departments, design laboratories, or anywhere an accurate voltage and current source is required.


Using Krohn-Hite's advanced reference voltage, the 523 provides precise and stable voltage from ±10 nVdc to ±110.99999 Vdc within ±4 ppm over 90 days (±1 ppm, 1 year), and precise current from ±10 nA to ±110.99999 mA within ±8 ppm over 90 days (±16 ppm, 1 year). It is an extremely quiet source, with noise measured at <7 μVrms over a 10 Hz to 100 kHz bandwidth (<2 μVrms, 0.1 Hz to 10 Hz).


The Krohn-Hite 523 has a 7½-digit display and all settings are entered via a membrane keyboard. Output settings can be modified using add/subtract functions, multiply/divide functions, and cursor control keys. Output 2-wire, 4-wire, and chassis ground can be set with a single key press or via the GPIB interface bus. The crowbar function can place the output in a safe mode when needed. The 523 output can be set to 0 volts, allowing the output sense to maintain a true 4-wire low-impedance zero output. It is also quickly forced to zero before range changes to prevent any "unexpected voltage".



Settling time:<10ms。
Line regulation: <±0.1ppm change for a 10% change from normal line voltage, typically no measurable change.
Load regulation 4-wire operation: <±0.1 ppm change from no load to 100 mA full load, typically no measurable change. Must be measured at the sense lead connection point with the load.
Compliance voltage limit: Settable in 1V steps from 1V to 110V. Compliance is limited to approximately 15% + 0.25V above the set value.
Switching time: Typically 300 ms.