Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
Krohn-Hite Model 526 Precision DC Power Supply/Calibration Power Supply

Krohn-Hite Model 526 Precision DC Power Supply/Calibration Power Supply

Model:526      Country of Origin:USA

Category:Precision Low-Noise DC Power Supply

Overview:

The Krohn-Hite Model 526 Precision DC Voltage/Current Source/Calibrator is a highly stable and repeatable DC voltage source and DC current source, providing N.I.S.T. traceable voltage and current for production, calibration laboratories, quality assurance and quality control departments, design laboratories, or anywhere an accurate voltage and current source is required.

Features
Specifications
Application Notes
Functions & Configuration


●Voltage range: ±100nV to ±110V, 4 ranges (Full Carry and Borrow for each Decade)

●Current range: ±10nA to ±110mA, 2 ranges (Full Carry and Borrow for each Decade)
●Resolution: 1ppm
●Accuracy: 20ppm (1 year).
●Stability (24 hours): 3ppm
●Settling time: 2ms
●Compliance voltage: 100V
●Settable voltage and current values
●Zero operation
● “Crowbar” zero reference
●Local and GPIB/optional LAN remote control
●Replaces 8200



Technical specifications

Voltage range: ±100nV to ±110V, 4 ranges,

Each decade has full carry and borrow capability

Current range: ±10 nA to ±110 mA, 2 ranges,

Each decade has full carry and borrow capability

Resolution: 1ppm

Accuracy: 1 year, 20ppm

Stability (24 hours): 3 ppm

Settling time: 2ms

Compliance voltage: 100 V

Settable voltage and current limits

Zero-crossing operation

"Protect" zero reference

Local and GPIB / optional LAN remote control

Replaces the analog Model 8200

 


General Description

The Krohn-Hite Model 526 Precision DC Voltage/ Current Source/ Calibrator is

A highly stable and repeatable DC voltage source and DC current source, providing

N.I.S.T. traceable voltage and current for production, calibration laboratories, qual

calibration assurance and quality control departments, design laboratories, or anywhere accurate voltage

and current sources are required.

The 526 provides ±100nVdc to ±111.1110Vdc within 20ppm and

Precise voltage for 1 year, providing precise current from ±10 nA to

±111.1110 mA within 50 ppm for 1 year. It has very low noise, at

noise measured over a 10Hz to 100kHz bandwidth of <12μVrms.

 


Decade control

The microprocessor used for decade control allows continuous use of one decade,

With full carry and borrow capability to and from more significant decades, for

ease of use and convenient manual operation. By using one decade control,

monotonic linear A/D measurement at any resolution can be achieved.

 


Display and front panel controls

A user-friendly 2 line 40 character display and six front panel decade

switch, with full carry and borrow, allowing fast and precise voltage and current

settings. The output setting can be modified using the front-panel decade switches and range keys

rent settings. The output is 2 wire, 4 wire via a single keypress or GPIB/LAN .

When needed, the protect function places the output in a safe mode. The 526 output can be set

to 0 V, allowing output sensing to maintain a true 4 -wire low-impedance output.

 


Ranges and resolution

The 526 provides 4 voltage ranges of 100mV, 1V, 10V and 100V, with resolution

rates of 100 nV, 1 μV, 10 μV and 100 μV respectively. Provides 2 current

ranges of 10 mA and 100 mA, with resolutions of 10 nA and 100 nA respectively.

 



Non-volatile memory

The 526 provides up to 32 stored output settings that can be recalled at any time.

 


Voltage, current and compliance limits

Select voltage and current limits to prevent the user from damaging sensitive circuits or the device under test

units, configurable from the front panel; hardware compliance voltage limits can also be set

120 V, 36 V, 26 V or 16 V.

 



Applications

The 526 is ideal for a wide range of applications, such as: high-speed, high-resolution A/D conversion

design, detection and calibration of devices; design

and certification of high-speed data logging and process control systems; calibration of digital voltmeters and multimeters; as an "embedded standard"

and/or simulator; design, testing,

simulation and certification of thermocouple, strain gauge and sensor instrumentation. It is also a replacement for the Model 8200 .