Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
SSI OE4201 Isolated Current Source 100kHz Bandwidth Voltage-controlled Current Source

SSI OE4201 Isolated Current Source 100kHz Bandwidth Voltage-controlled Current Source

Model:OE4201      Country of Origin:China

Category:Precision Low-Noise DC Power Supply

Overview:
Floating input-to-output isolation design
1 Hz to 100 kHz output bandwidth
Two output ranges: 2 mA/V and 200 mA/V
Input voltage range 5 mVrms to 0.5 Vrms
Maximum output current 100 mA


Features
Specifications
Application Notes
Functions & Configuration

Product Overview

    The OE4201 is a floating, isolated voltage-controlled current source that supplies current to other instruments. It offers two output gain ranges, 2 mA/V and 200 mA/V, with AC current frequencies from 1 Hz to 100 kHz. As a current source instrument, the OE4201 delivers high accuracy and excellent stability, with output essentially independent of load and external voltage variations, strong noise immunity, and fast response. It is well suited for use with sensitive AC instruments such as lock-in amplifiers, providing a simple way to generate precise currents from an AC voltage. The OE4201 uses a standard rack-mount chassis with a compact, clean, and rugged internal layout, smooth and reliable switching, and is easy to operate, adjust, and service.


Functional Block Diagram

image


Input

    Input voltage range        0.005Vrms-0.5Vrms

    Input frequency range        1 Hz-100 kHz

    Input impedance            50Ω

    Input peak voltage        ±0.707V max

Output

    Output mode            Single-ended

    Output current RMS      0.01 mA-100 mA

    Output load            0.1Ω-100Ω

    Rated output voltage        ≤1 Vrms

    Maximum output voltage        ±9 V (open circuit)

    Input-output gain       2mA/V or 200mA/V


Accuracy

Accuracy                 2% (typical)

                     5% (maximum)


Amplitude-frequency and phase-frequency characteristic curves


image

image

image

image


Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)

Inquiry Type: Message