Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
VITREK Model 4700 High-Precision High-Voltage Meter

VITREK Model 4700 High-Precision High-Voltage Meter

Model:Model 4700      Country of Origin:USA

Category:High-voltage meter HV meter

Overview:

Vitrek Model 4700 High-Precision High-Voltage Meter. The new Vitrek Model 4700 precision high-voltage meter offers the highest measurement accuracy, and its color touchscreen is very simple and easy to use. Vitrek uses DSP technology to provide excellent AC and DC voltage accuracy/stability and resolution, with precise high-voltage measurement up to 10kV RMS DC; 35kV, 70kV and 100kV high voltage available - SmartProbes. Model 4700 uses a compact and durable benchtop enclosure with high portability, providing immediate, direct high-voltage measurement, outperforming traditional high-voltage reference dividers, yet different from professional high-voltage dividers.

Features
Specifications
Application Notes
Functions & Configuration

4700-chart-mode-screen

Direct Measurement or HV-SMARTPROBE™, Your Choice

The Vitrek Model 4700 directly and precisely measures voltages with peaks up to 15KV, right out of the box, with no external probes. For 90% of hipot testers and other high voltage sources, this is already sufficient; however, if you need to expand the high voltage measurement range, simply add one or more optional 35KV, 70KV and 100KV HV-SmartProbes™. Vitrek HV-SmartProbes™ download their own calibration data and store it when plugged into the Model 4700, thereby achieving highly accurate calibrated readings and enabling any Vitrek HV-SmartProbe™ to be used with any Model 4700 high voltage meter.

The HV-SmartProbe's™ unique ultra-low TC attenuator design eliminates the use of voltage coefficient adders, while its reduced capacitance structure technology improves AC performance. In addition to the direct input terminals, the Model 4700 has two probe inputs - one for a probe that expands the measurement range, or two for high voltage differential measurements.


Superior Performance, Reflected in Design

Measurement integrity is our minimum requirement - whether it is a production line manufacturing high voltage medical imaging equipment, a national-level laboratory conducting breakthrough research, or a calibration laboratory certifying test equipment, tools must be carefully selected. To ensure the highest measurement accuracy, the Model 4700 takes more than 40,000 samples per second, then filters, resamples, scales and offset-corrects these samples to provide up to 60 enhanced readings per second - all using "error-free" mathematical algorithms. True RMS AC readings are read correctly, while DC measurements provide very stable ultra-fast processing. In addition, the Model 4700 provides VLF AC readings down to 0.01 Hz, as well as ripple, peak-to-peak, crest factor and fundamental frequency measurements.


High Voltage Test Automation

With the Model 4700's built-in Ethernet port, high-speed serial communication port or optional GPIB, automation of high voltage test requirements can be achieved. The Model 4700 is fully programmable, so you can select the measurement mode and bandwidth yourself, and then read readings at the desired frequency. The Model 4700 comes standard with a USB printer port to capture readings and print high voltage graphs, so that dips or overshoots in standard hipot tests can be recorded.



Features:

Accurate high voltage measurement up to 10kV RMS DC; 35kV, 70kV and 100kV high voltage available - SmartProbes™

Calibrate hipot testers, high voltage power supplies and insulation testers

Basic accuracy - 0.03% DC, 0.1% True RMS AC

Color touchscreen - for easy measurement selection and display

Connect to a computer via standard Ethernet, serial port, USB printer port and optional GPIB

Chart mode stores 300 readings to record high voltage source drift, ramp time, overshoot and voltage dips

Dual inputs provide differential voltage or phase-to-phase voltage measurement

High-speed DSP provides up to 60 filtered readings per second

True RMS AC measurement from 0.01Hz to 600Hz - covering from VLF to aviation frequencies

AC noise rejection 78dB - rock-solid 6-digit DC measurement

Optional lithium-ion battery pack provides 11 hours of operation on a single charge

EN61010 certification mark

Warranty extendable up to 3 years


Abbreviated 4700 Performance Specifications

Maximum Voltage Measurement (Input Impedance)

Direct Input Terminal

10KVDC, 10KVACrms (110 Meg ohms)

HVL-35 / HVP-35 Probe

35KVDC, 30KVACrms (200 Meg ohms)

HVL-35G Probe

35KVDC (10 Gig ohms)

HVL-70 Probe

70KVDC, 50KVACrms (400 Meg ohms)

HVL-70G Probe

70KVDC (20 Gig ohms)

HVL-100 Probe

100KVDC, 75KVACrms (600 Meg ohms)

HVL-100G Probe

100KVDC (30 Gig ohms)

HVL-150 Probe

140KVDC, 100KVACrms (1000 Meg ohms)


DC Voltage Measurement Accuracy (Resolution)

Direct Input Terminal

0.03% of reading + 0.03V (10mV)

HVL-35 / HVP-35 Probe

0.035% of reading + 0.07V (100mV)

HVL-35G Probe

0.25% of reading + 1.5V (1V)

HVL-70 Probe

0.04% of reading + 0.2V (1V)

HVL-70G Probe

0.35% of reading + 3.5V (1V)

HVL-100 Probe

0.05% of reading + 0.3V (1V)

HVL-100G Probe

0.5% of reading + 15 (10V)

HVL-150 Probe

0.08% of reading + 0.7V (10V)


AC Voltage Measurement Accuracy (Resolution)

Direct Input Terminal

0.12% of reading + 0.1V (10mV)

HVL-35 / HVP-35 Probe

0.1% of reading + 0.2V (100mV)

HVL-70 Probe

0.1% of reading + 0.4V (1V)

HVL-100 Probe

0.1% of reading + 0.6V (1V)

HVL-150 Probe

0.5% of reading + 1V (10V)


High Voltage Self Heating Effect

Direct Input Terminal

1.5 ppm of reading per KV2

HVL-35 / HVP-35 Probe

0.4 ppm of reading per KV2 / 0.75 ppm of reading per KV2

HVL-70 Probe

0.14 ppm of reading per KV2

HVL-100 Probe

0.14 ppm of reading per KV2

HVL-150 Probe

0.2 ppm of reading per KV2


General Specifications

AC/DC Voltage Measurement Resolution

Selectable 4, 5 or 6 digits

Measurement Functions

DC Voltage, True RMS AC Voltage, Ripple, Peak to Peak, Crest Factor & Frequency Measurement (4 digits 0.01 Hz to 600Hz)

Measurement Time

Selectable down to 16mS (60 readings per sec.)

Maximum Input to Common Terminal

3 KV Peak for 1 sec, no damage

Accuracy Specifications

Valid one year ± 5C from Cal temperature

Interfaces

LAN (Ethernet), RS232/Serial and USB printer port standard. GPIB optional.


Environmental/Physical

Operating Environment

0 to 50C,<85% RH (non-condensing)

Dimensions

218mm (8.5″) wide x 130mm (5″) high x 253mm (10″) deep, nominally

Weight

2.4kg max (4kg shipping)


Power

AC Source

45 to 450Hz, 100 to 265Vrms at

DC Source

11 to 16Vdc at<1.2A, using a center positive 2.5mm DC power connector

BP-47 Battery Option

Up to 11 hours continuous operation



Standard Accessories

The 4700 is shipped with an ISO 17025 cal cert with data and uncertainties, direct input test leads, chassis ground lead, operator’s manual, and external power supply. All probes ship with an ISO 17025 cal cert with data and uncertainties. The HVP handheld probes comes with a detachable probe tip and the HVL series probes ship with a toroid corona shield.

Warranty

3 year extended parts and labor warranty with no charge registration and annual factory calibration. 1 year standard warranty.