Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
IWATSU SS-240 and SS-250 IWATSU High-Frequency AC/DC Hall Current Probe

IWATSU SS-240 and SS-250 IWATSU High-Frequency AC/DC Hall Current Probe

Model:SS-240/SS-250      Country of Origin:Japan

Category:AC/DC Current Probe

Overview:

Wide bandwidth - DC to 100 MHz (SS-250)/DC to 50 MHz (SS-240A)

Features
Specifications
Application Notes
Functions & Configuration

image.pngSS-250/SS-240A



■Supports various applications

Displays its capabilities in full force in current waveform observation and wide-band applications such as switching power supplies, optical disc manufacturing lines, and semiconductor power devices.



■Features

 

image.pngLow noise characteristics for easy milliampere order observation


image.pngWide bandwidth - DC to 100 MHz (SS-250)/DC to 50 MHz (SS-240A)


image.pngHigh sensitivity and wide bandwidth implemented through use of thin-film Hall element

 

image.pngPower can be provided directly from the oscilloscope
(DS-5600A/DS-5400A series of oscilloscopes with DS-579 : Probe power option)


image.pngClamp type, enabling easy measurement without cutting the electrical circuit

 

image.pngEquipped with a function that provides simple protection for excessive input

 

image.pngCan also be used with measuring instruments that do not have a power supply for probes (power can be provided through the optional probe power supply PS-26)




■Specifications

Item

SS-250

SS-240A

Bandwidth

DC to 100 MHz
(-3dB)

DC to 50 MHz
(-3dB)

Maximum input current

Maximum input range

30 A rms

30 A rms

Maximum peak current

50 A peak, non-continuous

50 A peak, non-continuous
50 A peak at pulse width <= 10 μs

Output sensitivity

0.1 V/A

Sensitivity accuracy

•±1.0% of reading ±10 mA for probes only (in the range from 0 to 30 A rms, DC, and AC 45 to 66 Hz)
•±2.0% of reading for probes only (50 A peak or less and over 30 A rms, DC, and in the range of AC 45 to 66 Hz)

Noise

2.5 mA rms or less (observation using an oscilloscope with a 20 MHz band)

Power consumption

5.3 VA max.

5.6 VA max.

Power supply voltage

±12 V ±0.5 V

Operating temperature and humidity

0°C to +40°C, 80% RH or less
(no condensation)

Storage temperature and humidity

-10°C to +50°C, 80% RH or less
(no condensation)

Operating elevation

2000 m or less (air pressure approx. 79 kPa), indoor

Effects of external magnetic field

5 mA max. or equivalent (in DC, 60 Hz, 400 A/m AC magnetic field)

20 mA max. or equivalent (in DC, 60 Hz, 400 A/m AC magnetic field)

Maximum usable circuit voltage

300 V, CAT I (insulating conductor)

Conductor diameter that can be measured

ø 5 mm

Cable length

Sensor cable

Approx. 1.5 m

Power cable

Approx. 1 m

Size

Sensor part

Approx. 175 (W) x 18 (H) x 40 (D) mm

Termination part

Approx. 27 (W) x 55 (H) x 18 (D) mm

Weight

Approx. 240 g

Approx. 230 g

Complied with standards

Safety

EN61010-2-032:2002
Measurement category I (expected overvoltage: 1500 V),
Pollution degree: 2

EMC

EN61326:1997+A1:1988+A2:2001

Accessories

Instruction manual (1),
hard case (1)

Instruction manual (1),
soft case (1)
 

* Values for performance/accuracy items are at 23°C ±5°C and 30 minutes after power-on.



■ Characteristics figures

 

SS-250 Continuous maximum input range (frequency derating)

image.png 

 

SS-240A Continuous maximum input range (frequency derating)

 

 

* These current probes can be used as-is with oscilloscopes that feature power supply connectors for active probes. Current probes can also be used with oscilloscopes without power supply connectors for active probe, when used in combination with the optional power supply (PS-26).

 

* With the power supply for current probe PS-26, if the current being measured is large, it may not be possible to use two SS-250/SS-240A units at the same time.

 

 

 

■Caution

1.Use this product in circuits that do not exceed the maximum usable circuit voltage, so as to avoid accidents such as short-circuits and physical injuries.

2.Do not use this product with bare conductors, so as to avoid accidents such as physical injuries and short-circuits when the leading end of the clamp core is opened.

 


Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)

Inquiry Type: Message