Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
Cybertek CP9000LF Series (60A~60kA/600kHz~1MHz/10kV insulation) Low-Frequency Current Probe

Cybertek CP9000LF Series (60A~60kA/600kHz~1MHz/10kV insulation) Low-Frequency Current Probe

Model:CP9000LFSeries      Country of Origin:China

Category:AC/DC Current Probe

Overview:

Typical accuracy ±1%

Maximum output voltage ±6Vpk


Features
Specifications
Application Notes
Functions & Configuration

CP9000LF Series flexible current probes are low-frequency flexible probes with dual-range design.

They can achieve a wide current measurement range, with a range design from 60A to 60kA, ensuring 1% accuracy in the middle of the loop, with a typical accuracy of 2% throughout the entire loop (except at the loop junction), a bandwidth of up to 600kHz (700mm coil circumference) or 1MHz (300 mm coil circumference), a typical probe loop outer diameter of 8mm, and a withstand voltage of up to 10kVpk, making them very suitable for low-frequency high-current and high-power testing applications.



Features:

●The coil is lightweight and flexible and can be freely plugged and unplugged, allowing detection of many places that hard probes cannot reach, easily achieving connection with the object under test;

●Insertion loss is almost zero, only a few picohenries, causing nearly zero interference to the object under test;

●Standard BNC output interface, making it convenient to connect with oscilloscopes, data loggers, digital voltmeters, etc., to observe current waveforms;

●9V battery power supply or external 12V DC power supply, making use more flexible and convenient; overcurrent alarm function, a more user-friendly design;

●The length of the probe loop and connecting cable can be customized according to customer requirements to meet testing requirements in special applications.

ElectricalParameters

Measurement conditions:23℃; 60%RH; the measured wire passes through the center of the probe sensing loop