中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
Micsig High-Frequency AC/DC Current Probes CP253B, CP503B, CP1003B New

Micsig High-Frequency AC/DC Current Probes CP253B, CP503B, CP1003B New

Model:CP253B、CP503B、CP1003B      Country of Origin:China

Category:AC/DC Current Probe

Overview:

The Micsig high-frequency AC/DC current probe offers a bandwidth of up to 100 MHz for fast, accurate current capture;

accuracy up to 1% across its range meets most test requirements; the dual 6 A / 30 A ranges

improve signal-to-noise ratio and make low-current measurements easy; one-button degauss and auto-zero, plus overload protection;

compact, lightweight design with a small jaw that still clamps conductors up to 5 mm in diameter;

universal BNC interface compatible with oscilloscopes of any brand.


Features
Specifications
Application Notes
Functions & Configuration

1. BNC Interface

Standard BNC interface, compatible with all oscilloscopes.

2. Compact, Refined Design

Compact and easy to operate, fits in one hand. 

Suitable for a wide range of complex scenarios.

3. Degaussing and Auto-Zero in One Step

Press the "Zero" button; it lights up and the probe performs degaussing and zeroing.

4. Confident Measurement with Overload Indicator

When current overload occurs, the status indicator of the corresponding range button flashes.

5. Measure Anywhere with Confidence

Comes standard with an aviation-grade dedicated carrying case, convenient for outdoor measurements.

6. Measuring High-Frequency Current Signals

The high-frequency AC/DC current probe handles signals above 20 MHz with ease (CH1 yellow waveform in the figure). 

A low-frequency AC/DC current probe measuring the same signal shows complete distortion (CH2 blue waveform in the figure).

7. Observing Inrush Current

Accurately captures the inrush current waveform when a power adapter starts up.



Applications

New energy vehicle design, switching power supply design, electrical engineering experiments, semiconductor device design, avionics design, inverter/transformer design, electronic ballast design, industrial control/consumer electronics design, engine drive design, power electronics and electric drive experiment design, and more.


Product specifications table

High-frequency AC/DC current probe modelsCP253BCP503BCP1003B
Bandwidth25MHz50MHz100MHz
Rise time≤14ns≤7ns≤3.5ns
Power supply methodStandard adapter
Power supplyDC 5V 3A
Delay<30ns(6A)
<30ns(30A)
Range6A (2X attenuation) / 30A (10X attenuation)
Output sensitivity1V/2A(6A)
1V/10A(30A)
DC accuracy (typical)

±1%±10mA(6A)

±1%±50mA(30A)

Measurement range20mA~6Apk(6A)
50mA~30Apk(30A)
Maximum measurement current30Apk,60Apk-pk,21.21Arms
Noise≤1.4 mA RMS (measurement bandwidth limited to 20 MHz; range 30A, 10X attenuation)
Maximum operating voltageCAT I 300V
Maximum floating voltageCAT I 300V
Maximum conductor diameter5mm
Overload indicationButton light flashing