Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
CYBERTEK VP5200A Zhiyong High Voltage Differential Probe

CYBERTEK VP5200A Zhiyong High Voltage Differential Probe

Model:VP5200A      Country of Origin:China

Category:High-voltage differential probe

Overview:

The VP5200A high-voltage differential probe is designed for the measurement of high-voltage differential signals and meets the needs of floating measurements.

Its bandwidth reaches 60MHz, meeting the needs of most test systems;

A wide selection of ranges is available, and its differential measurement voltage range meets the requirements of most test circuits;

Electronic touch buttons provide a longer service life.

Features
Specifications
Application Notes
Functions & Configuration
ModelMax Input Differential VoltageBandwidthAttenuation Ratio
VP5200A1500V60MHz50X/500X


1. Overview

The VP5200A high-voltage differential probe is designed for measuring high-voltage differential signals and meets the needs of floating measurements. Its bandwidth reaches 60MHz, meeting the needs of most test systems; a rich selection of ranges is available, and its differential measurement voltage range meets the requirements of most test circuits; electronic touch buttons provide a longer service life; it features a 5MHz bandwidth limit function option, and the 5MHz frequency bandwidth meets the measurement of the switching frequency of FETs in most switching power supplies and can filter out higher-frequency noise and interference; it has an audible and visual alarm function, and the audible alarm can be manually turned off, providing a more user-friendly design; the probe is equipped with a standard BNC output interface and can be used with oscilloscopes from any manufacturer (the oscilloscope input impedance must be set to 1MΩ) to measure the waveform of the circuit under test. The probe has good common-mode noise rejection capability, and the input end has high input impedance and low capacitance, enabling accurate and high-speed measurement of differential voltage signals. It can be widely used in R&D, debugging, or maintenance of switching power supplies, inverters, electronic ballasts, inverter home appliances, and other electrical power devices.


2. Applications
■    Floating voltage measurement
■    Inverters
■    Switching power supply design
■    Welding and electroplating power supplies
■    Induction heating and induction cookers
■    Motor drive design
■    Electronic ballast design
■    CRT monitor design
■    Inverter and UPS power supplies
■    Inverter home appliances
■    Power conversion and related designs
■    Electrical engineering experiments
■    Low-voltage apparatus testing
■    Power electronics and electric drive experiments, etc.
 
3. Product and Accessories Description
■    Probe main body description
 
1)  VP5200A probe main body
Model
VP5200A
Alligator clip (CK-261)
CATIII 1000V
CATIV 600V
Piston probe clip (CK-282)
CATIII 1000V
Test hook (CK-284)
CATIII 1000V
High-voltage differential input cable (CK-350)
CATIII 1000V
Coaxial cable output line (CK-310)
Double-ended BNC coaxial cable, length 1m
Power adapter (CK-612)
DC12V/1A
 
4.Electrical Specifications

Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)

Inquiry Type: Message
Model
VP5200A
Bandwidth (-3dB)
DC to 60MHz
Rise Time
≤5.8ns
Accuracy
±2%
Range Selection (Attenuation Ratio)
50X/500X
Max Differential Measurement Voltage (DC + Peak AC)
50X
150V
500X
1500V
Max Common-Mode Input Voltage
(Input-to-Ground Voltage Vrms)
600V CATIII
1000V CATII
Input Impedance
Single-ended to ground
4MΩ
Between two inputs
8MΩ
Input Capacitance
Single-ended to ground
<4pF