Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
HIOKI 8860-50/ 8861-50 Hioki Memory Recorder Oscilloscope

HIOKI 8860-50/ 8861-50 Hioki Memory Recorder Oscilloscope

Model:8860-50/ 8861-50      Country of Origin:USA

Category:Data Acquisition and Playback

Overview:

As an oscilloscope and as a data logger, it is suitable for data acquisition and recording in various situations.

Features
Specifications
Application Notes
Functions & Configuration

●Operating speed increased 3 times compared to previous models

●Maximum 64-channel/128-channel multi-channel data acquisition (using 8958 scanning unit)

●20MS/s high-speed sampling readout

●Equipped with various interfaces such as LAN/USB/PC card slot

●A rich lineup of input units for temperature, FFT, strain, F/V, charge, etc.

 

The 8860-50 and 8861-50 main units alone cannot be used; please install separately sold input units in the main unit and use them together.
*In any case, one type of memory expansion board is required. For the 8861-50, two of the same type are required; please specify when ordering.


Model

8860-50

8861-50

Unit

Maximum 4 units

Maximum 8 units

Number of input channels

16 analog channels + 16 logic channels
64 analog channels + 16 logic channels (using 8958)

32 analog channels + 16 logic channels
128 analog channels + 16 logic channels (using 8958)

Measurement range
(20 divisions f.s.)

5mV to 20V/division, 12 range settings (using 8956)
Resolution: 1/100 of range

5mV to 20V/division, 12 range settings (using 8956)
Resolution: 1/100 of range

Maximum input voltage

DC 400V (when using 8956)

DC 400V (when using 8956)

Frequency characteristics

DC to 10MHz (when using 8956)

DC to 10MHz (when using 8956)

Power supply

AC 100~240V, 50/60Hz
(maximum 220VA when not using the print unit)
DC 12V system (when 9684 is installed)

AC 100~240V, 50/60Hz
(maximum 280VA when not using the print unit)
DC 12V system (when 9684 is installed)

Dimensions and weight

330W × 250H × 184.5Dmm
8kg (when not using the print unit)

330W × 250H × 284.5Dmm
10.5kg (when not using the print unit)

Time axis of the storage function
(when using the storage function)

5μs ~5 minutes/div, 26 range settings,
Sampling speed:
Fixed: 1/100 of the time axis range,
Arbitrary:  External sampling; the time axis can be set by the sampling period; sampling speeds for 2 systems can be set

Measurement functions

Storage (high-speed recording), Recording (real-time recording), Storage and recording (real-time recording + high-speed recording), FFT (frequency analysis), Real-time save function (can save data to media in real time)

Memory capacity

Analog 12bit × 32MW/ch (1ch on 8860-50, 2ch on 8861-50) to 2MW/ch (16ch on 8860-50, 32ch on 8861-50) *Expandable up to 32 times. (using optional memory expansion board)

Storage media

PC card TYPE II slot × 2 (standard),  hard disk (memory option)

Recording paper

[Print unit - option]: A4: 216mm×30m or A6: 112mm×18m, roll thermal paper, recording speed: maximum 25mm/sec

Display

10.4-inch TFT color LCD (SVGA, 800×600 dots)

Interface

GP-IB (PC card), USB2.0 (standard socket A), LAN (HTTP/FTP/send, etc.),  external display output (15-pin D-sub, SVGA output)

Accessories

Power cord × 1,  ground adapter × 1,  input wire labels × 1,
Waveform viewing software ( Wv+ communication command table ×1)