Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
TEKTRONIX 370B/371A transistor curve tracer CURVE TRACER

TEKTRONIX 370B/371A transistor curve tracer CURVE TRACER

Model:SONY-TEK 370B      Country of Origin:Japan

Category:Power Transistor Curve Tracer

Overview:

The Tektronix 370B is a highly representative transistor curve tracer. It is a professional test instrument offering the following technical specifications:
Interactive programmable control  All interactive programmed measurements are performed via the distinctive front panel or GPIB.
The Tektronix 370B curve tracer provides supply capability up to 20 A/2000 V and measurement resolution of 1 pA and 50 V. The 370B meets the test requirements of many transistor products. It performs DC parameter characterization on transistors, thyristors, diodes, SCRs, MOSFETs, optoelectronic devices, solar cells, solid-state displays, and other semiconductor devices.


Features
Specifications
Application Notes
Functions & Configuration

R-C.jpg

The Tektronix 370B is a highly representative transistor curve tracer. The Tektronix 370B is a professional test instrument, and here are its detailed technical specifications:
Interactive programmable control — all interactive programmed measurements are performed via the distinctive front panel or GPIB.
The Tektronix 370B curve tracer provides supply capability up to 20 A/2000 V with measurement resolution down to 1 pA and 50 V. The Tektronix 370B meets the test requirements of many transistor products. The 370B performs DC parameter characterization on transistors, thyristors, diodes, SCRs, MOSFETs, optoelectronic devices, solar cells, solid-state displays, and other semiconductor devices.


Key features and performance:


  • Maximum current — with the control set to 200 mA, STEP AMPLITUDE set to 20x, and STEP AMPLITUDE set to 10x.

  • High-resolution DC parameter measurements on the 370B (resolution down to 1 pA or 2 µV)
    High-voltage and current sourcing on the 371B (up to 3,000 V or 400 A)
    Built-in cursor measurements — dot, window, and function lines
    Kelvin sensing
    Sweep measurement mode
    Waveform comparison and averaging
    Fully programmable
    1.44 MB floppy disk drive for storing curve setups and bitmaps
    Direct hard copy via third-party printers


Available peak power

16, 80, and 400 V ranges - 0.08, 0.4, 2, 10, 50, 220 W.

2,000 V range - 0.08, 0.4, 2, 10, 50 W.

Variable collector supply setting, expressed as a percentage of maximum peak voltage - 0 to 100%, in 0.1% increments.

Loop compensation (typical) range - at least 100 pF.

Step generator

Accuracy

Increment - 1.5%.

Absolute - less than 1.5% of total output + 3% x step amplitude setting + 1 mV or 1 nA.

Offset control range - varies between -10 and +10 times the step amplitude.

Resolution - step amplitude setting x 1%.

Current mode

Amplitude range -50 nA to 200 mA, in 1-2-5 sequence (21 steps).

Maximum current - at control setting of 200 mA, STEP AMPLITUDE set to 20x, STEP AMPLITUDE set to 10x.

Maximum voltage - at least 10 V.

Maximum reverse bias current - 10 times the step amplitude.

Maximum reverse voltage - less than 15V.

Ripple plus noise - less than 0.5% x step amplitude + 10 nA.

Voltage mode

Amplitude switch range - 50 mV to 2 V, in 1-2-5 sequence (every 6 steps).

Maximum voltage -20 times step amplitude.

Maximum current - at least 500 mA at 10 V or below, at least 200 mA at 15 V, at least 10 mA at 40 V.

Short-circuit current limit -500 mA, +50%, -20%.

Maximum reverse bias current - 10 times the step amplitude.

Maximum reverse current - less than 20 mA.

Ripple plus noise - less than 0.5% x step amplitude + 10 mV.

Step rate - 2x line frequency (1x line frequency in AC collector supply mode). Step occurs when collector voltage is 0.

Pulse step  -80 µs or 300 µs wide, ±10%.

Step and offset polarity - When " Step Generator Polarity Invert" is disabled, corresponds to collector supply polarity. When STEP GENERATOR POLARITY INVERT is selected or the CONFIGURATION switch is set to BASE COMMON, opposite to collector supply polarity. BASE COMMON configuration disables STEP GENERATOR POLARITY INVERT.

Number of steps - ranges from 0 to 10.

Auxiliary power supply:

Range  --40 to +40 V, step resolution 20 mV.

Accuracy (typical) -within 50 mV + 1.5% of total output.

Output current - at least 100 nA at ±20 V.

At least 10 mA at ±40 V.

Ripple plus noise - less than 50 mV p-p.

Vertical deflection system

Collector/Base current

Range - from 1 µA/div to 2 A/div in 1-2-5 sequence.

X10 MAG extends maximum sensitivity to 100 nA/div (1 nA resolution).

Accuracy (typical) - within 2% of WINDOW cursor reading + 0.1 x VERT/DIV setting.

Emitter current

Range - from 1 nA/div to 2 mA/div in 1-2-5 sequence. X10 MAG extends maximum sensitivity to 100 pA/div.

Accuracy (typical) - within 2% of WINDOW cursor reading + 0.1 x VERT/DIV setting + 1 nA.

Maximum displayed noise or ripple - depends on maximum peak voltage setting.


Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)