Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Technical Services & Solutions

Technical support and after sales service

Technical Services & Solutions

Fully compliant with IEC61000 EMC test systems (IEC61000-3-2, IEC61000-3-3, IEC61000-3-11, IEC61000-1000-4-13, IEC61000-4-17, IEC61000-4-29) 3-12, IEC61000-4-11, IEC6

Published: 2022-11-27 Views: 次

IEC61000 EMC Test System – ISO17025 Certified

Fully compliant with IEC61000 EMC test systems (IEC61000-3-2, IEC61000-3-3, IEC61000-3-11, IEC61000-3-12, IEC61000-4-11, IEC61000-4-13, IEC61000-4-17, IEC61000-4-29)

N4L's IEC61000 EMC test system range provides a complete turnkey solution for EMC immunity testing. The N4A AC+DC power source, PPA55x1 and impedance network, and intuitive EMC test software (IECSoft) combine to form a simple, convenient, compliant test package.

N4L is the world's only manufacturer of IEC61000 EMC test systems*, with an on-site UKASISO17025calibration laboratory, providing IEC61000-3-2, IEC61000-3-3, IEC61000-4-7 and IEC61000-4-15 certification. Calibration and traceability are an important aspect of any EMC test solution, and the coverage provided by N4L's UKAS laboratory is comprehensive. N4L's IEC61000-4-15 calibration procedure is particularly noteworthy as it covers the entire test protocol detailed in Annex C of IEC61000-4-15. It is common for specific parameters in IEC61000-4-15 (the d parameter is often omitted in calibration procedures) to go untested during typical flicker calibration because it is difficult to provide traceability for such measurements. All tests in the Annex C test protocol are included within the scope of N4L's certification and calibration procedures.

IECSoft is an integral part of the EMC test package, integrating various hardware components and displaying data in a clear manner. As an example of IECSoft's flexibility, users can send comprehensive test data to external customers or colleagues in the design department. This is very useful because design engineers can replay harmonic and flicker tests in real time, not only visualizing the test results (in report form) but also determining device performance throughout the entire test. An example of this might be that the final report of an IEC61000-3-2 test results in the EUT (device under test) failing on harmonic 5; IECSoft can replay the behavior of harmonic 5 throughout the test, which can significantly reduce debugging time for design engineers when such compliance tests fail. In the past, EMC test systems only provided detailed information on harmonic failure levels in summary form, but no such limitation applies to the N4L EMC test system.

Product Image

Example test system configuration

Below are examples of test system configurations that provide harmonic and flicker test solutions compliant with the latest IEC/EN standards listed in the table at the top of this page.

3kVA (maximum 10Arms) single-phase IEC61000 EMC test system


Measurement Requirements
Compliance
Analyzer

Impedance network

Calibration (Optional)

AC power source
IEC61000 EMC testing

10Arms Single-Phase
IEC61000-3-2 IEC61000-3-3 IEC61000-4-11*IEC61000-4-13 IEC61000-4-14 IEC61000-4-17 IEC61000-4-28

IEC61000-4-29*

PPA5500 Power Analyzer Front View, No BG Cropped 200px

PPA5511 harmonic and flicker analyzer

+
IMP161 Front Panel 200px

IMP161 impedance network

+
UKAS_Logo
+

n4a06_small
N4A03 Programmable Power Supply


6kVA (max 20Arms) Single-Phase IEC61000 EMC Test System


Measurement Requirements
Compliance
Analyzer

Impedance network

Calibration (Optional)

AC power source
IEC61000 EMC testing

16Arms single-phase
IEC61000-3-2 IEC61000-3-3 IEC61000-4-11*IEC61000-4-13 IEC61000-4-14 IEC61000-4-17 IEC61000-4-28

IEC61000-4-29*
PPA5500 Power Analyzer Front View, No BG Cropped 200px

PPA5511 harmonic and flicker analyzer

+
IMP161 Front Panel 200px

IMP161 impedance network

+
UKAS_Logo
+

n4a06_small
N4A06 programmable power supply


18kVA (maximum 20Arms per phase) three-phase IEC61000 EMC test system


Measurement Requirements
Compliance
Analyzer

Impedance network

Calibration (Optional)

AC power source
IEC61000 EMC testing

20Arms/phase three-phase
IEC61000-3-2 IEC61000-3-3 IEC61000-3-11 IEC61000-3-12 IEC61000-4-11*IEC61000-4-13 IEC61000-4-14 IEC61000-4-17 IEC61000-4-28 IEC61000-4-29*

IEC61000-4-34*

PPA5500 Power Analyzer Front View, No BG Cropped 200px

PPA5531 harmonic and flicker analyzer

+
IMP161 Front Panel 200px

IMP163 Impedance Network (IMP161 shown)

+
UKAS_Logo
+

n4a06_small
N4A18 Programmable Power Supply (N4A03 shown)


30kVA (max 32Arms per phase) Three-Phase IEC61000 EMC Test System


Measurement Requirements
Compliance
Analyzer

Impedance network

Calibration (Optional)

AC power source
IEC61000 EMC testing

32Arms/phase Three-Phase
IEC61000-3-2 IEC61000-3-3 IEC61000-3-11 IEC61000-3-12 IEC61000-4-11*IEC61000-4-13 IEC61000-4-14 IEC61000-4-17 IEC61000-4-28 IEC61000-4-29*
IEC61000-4-34*

PPA5500 Power Analyzer Front View, No BG Cropped 200px

PPA5531 harmonic and flicker analyzer

+
IMP161 Front Panel 200px

IMP323 impedance network (IMP161 as shown)

+
UKAS_Logo
+

n4a06_small
N4A30 Programmable Power Supply (N4A03 shown)


67kVA (max 75Arms/phase) three-phase IEC61000 EMC test system


Measurement Requirements
Compliance
Analyzer

Impedance network

Calibration (Optional)

AC power source
IEC61000 EMC testing

75Arms/three-phase
IEC61000-3-2 IEC61000-3-3 IEC61000-3-11 IEC61000-3-12 IEC61000-4-11*IEC61000-4-13 IEC61000-4-14 IEC61000-4-17 IEC61000-4-28 IEC61000-4-29*

IEC61000-4-34*

PPA5500 Power Analyzer Front View, No BG Cropped 200px

PPA5531 harmonic and flicker analyzer

+
IMP161 Front Panel 200px

IMP753 Impedance Network (IMP161 shown)

+
UKAS_Logo
+

n4a06_small
N4A67 Programmable Power Supply (N4A03 shown)

*Full compliance requires external switching, please contact us for more information

Features and benefits

0.01% basic accuracyFrequency range DC and 10mHz to 1MHz
Fully compliant with IEC61000-3-2Fully compliant with IEC61000-3-3
Fully compliant with IEC61000-3-11Fully compliant with IEC61000-3-12
Components compliant with IEC61000-4-11Fully compliant with IEC61000-4-13 standard
Fully compliant with IEC61000-4-14 standardFully compliant with IEC61000-4-28
Compliant with IEC61000-4-29Fully compliant with IEC61000-4-34
High-precision internal shunt superior to any external shunt in accuracy5 mm phase accuracy, required for low power factor applications
50 Arms (1000 Apk) and 1000 Vrms (3000 Vpk) direct inputStandard current (50Arms) option
High-speed sampling on all channelsTrue real-time analysis with no measurement gaps
1, 2 or 3 phase versions
Master-slave mode for 4, 5 or 6 phases
Real-time numeric, table, graph, and oscilloscope display
Simple BNC connection for N4L shunts, suitable for high-current applicationsRS232, IEEE 488, USB, LAN, torque, speed and expansion ports

 *according to N4L research July 2016
ManualDocumentation
EMC_Test_Systems_Nov_2019PDF, 3,334kbPPA55xx_user manualPDF, 1.95Mb
PPA5531_Brochure。PDF, 4,494kbPPA55xx Communication ManualPDF, 840kb
IMP16x_32x_75x_BrochurePDF, 995kbPPA55xx N4L Startup GuidePDF, 3.58Mb

IECSoft User Manualvo l 1PDF, 13.8Mb

IECSoft User Manual Volume 2PDF, 9.9Mb

IECSoft User Manual Volume 3PDF, 9.2Mb

Power_Analyzer_Product_SelectorPDF, 236kb