Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Technical Services & Solutions

Technical support and after sales service

Technical Services & Solutions

What are the main performance parameters of optically isolated measurement?

Published: 2024-01-05 Views: 次

In the field of optically isolated measurement, understanding the key performance parameters of the equipment is essential for selecting the right measurement device. An optical isolator is a device used for optical signal transmission that ensures the signal can travel in only one direction, thereby preventing reflections and echoes from affecting the system. So, what are the main performance parameters of optically isolated measurement?

1. Isolation and common-mode rejection ratio (CMRR)

Isolation is one of the key performance parameters of an optical isolator; it represents the ratio of transmission loss in the two directions. The higher the isolation, the better the isolator's performance. Isolation is typically expressed in decibels (dB), and optically isolated probes can achieve at least -160 dB. In practice, the isolation of an optical isolator should be selected according to the specific requirements of the system.

2. Signal bandwidth 

Signal bandwidth refers to the difference between the highest and lowest frequencies of the harmonics contained in a signal—that is, the frequency range the signal occupies. For example, consider a square wave formed by superimposing several sine waves; its lowest frequency component is its fundamental frequency. Optically isolated probes range from 200 MHz to 1.5 GHz.

3. Temperature stability

Temperature stability refers to how stable the isolator's performance is across different temperatures. The better the temperature stability, the smaller the performance variation of the isolator across temperatures. In practice, an optical isolator with good temperature stability should be selected according to the specific requirements of the system.

4. Voltage withstand capability

Voltage withstand capability refers to the isolator's ability to operate in high-voltage environments. The better the voltage withstand capability, the more stable the isolator's performance under high voltage. In practice, an optical isolator with good voltage withstand capability should be selected according to the specific requirements of the system.

5. Service life

Service life refers to how long an optical isolator can operate continuously under normal operating conditions. The longer the service life, the higher the isolator's reliability. In practice, an optical isolator with a long service life should be selected to ensure long-term stable operation of the system.

      6. Accuracy and delay

        High-accuracy measurement requires the sensor to maintain high-accuracy data acquisition across the full range over extended periods, typically with accuracy better than 1%.

      7. Compatibility

        Optically isolated probes are usually expensive, and if a probe's versatility is limited, it can greatly affect the customer's user experience and cost investment. The PMK FIREFLY FF-1500 is the world's first high-performance general-purpose optically isolated probe with a fanless design. For more information, please contact our selection engineers directly.


What are the main performance parameters of optically isolated measurement? Understanding the main performance parameters of optically isolated measurement is crucial for selecting the right optical isolator. In practice, an optical isolator with suitable performance parameters should be selected according to the specific requirements of the system. If you have any questions about the performance parameters of optical isolators, you are welcome to consult the website customer service of Ligao Jiechuang.