IWATSU VOAC7523H/7522H/7520H/7521H Iwatsu Digital Multimeter
Model:VOAC7523H/7522H/7520H/7521H Country of Origin:Japan
Category:Digital Multimeter DMM
Overview:
A single VOAC7523H/7520H unit features two DC measurement input channels and a dual display, enabling standard DC voltage measurement. Two units are required, saving installation space and improving measurement speed. The VOAC7522H/7521H has one input channel and a dual display, allowing current or frequency measurement simultaneously with voltage measurement. The VOAC7523H/7522H achieves high-resolution DC voltage measurement down to 0.1 μV and AC voltage bandwidth up to 300 kHz.
Features
Specifications
Application Notes
Functions & Configuration
Full scale, 509999
The highest full-scale count among 5.5-digit models. (Iwatsu Test Instruments Corp. research, November 2004)
Isolated 2-channel input with dual display (VOAC7523H/7520H only)
Provides two DC measurement inputs. The two channels are isolated from each other. Voltage comparison between two different circuits or potential difference measurements can be performed easily on components within the same circuit. A single VOAC7523H/7520H unit can perform DC voltage measurements that normally require two units, saving installation space and improving measurement speed. The VOAC7523H/7520H also features a dual display that shows the measured value for another function. For example, changing input cable connections or switching functions is required when measuring a different function with an existing single-display multimeter. A single VOAC7523H/7520H unit can perform both types of measurement simultaneously.
Dual Display
Traditionally, cable disconnection and function switching require different types of measurements. A single VOAC752xH series unit can perform measurements that would otherwise require multiple units, improving measurement efficiency. For example, when measuring power consumption (apparent power, VA), simultaneous voltage and current measurement enables real-time power measurement.
Multi-Function Interface
RS-232 is standard. LAN (Ethernet 10BASE-T) or GP-IB interfaces are available as options.
Long-Interval Measurement up to 3000 Hours
Interval measurements from 10 ms to 3600 s, with data logging of up to 3000 time-stamped readings and a maximum measurement duration of 3000 hours. Timestamp resolution is 10 ms.
True RMS measurement
All series models can measure true RMS AC voltage and AC current.
DIO (digital input/output) output for production line use (optional)
Combining trigger and open-collector outputs with 5-step pass/fail judgment levels makes production line use convenient.
*
Accuracy (±X% of reading +Y digits) indicated by X+Y
The measuring accuracy indicated below can be obtained for a year following the calibration of the instrument.
1. Typical Sample Rate and Resolution
Sample Rate
Resolution
Reading Rate
Hum Rejection
SLOW
5.5-digit
approx. 4 times/sec
Yes
MID
5.5-digit
approx. 20 times/sec
Yes
FAST
4.5-digit
approx. 100 times/sec
N/A
2. DC Volt (DCV) 50mV range is for the VOAC7523H / 7522H only.
Range
Resolution
Input Resistance
Accuracy*
5.5-digit
4.5-digit
SLOW/MID
FAST
50mV
0.1μV
1μV
100MW or more
0.025+10
0.025+15
500mV
1μV
10μV
1000MW or more
0.012+5
0.012+2
0.012+10
0.012+7
5V
10μV
100μV
50V
100μV
1mV
approx. 10MW
0.016+5
0.016+10
500V
1mV
10mV
0.016+2
0.016+7
1000V
10mV
100mV
The accuracy in the 50mV and 500mV ranges is specified after zero compensation through the REL operation.
Sample rate in the 50mV range SLOW/MID: Approx. 0.5 times/sec, FAST: Approx. 50 times/sec
Max. input voltage:
50mV to 5V range ± 800V (continuous) 50V to 1000V range ± 1100V (continuous)
Resolution and noise rejection
Resolution
Sample Rate
NMRR
CMRR
5.5-digit
SLOW
55dB or more
120dB or more
5.5-digit
MID
55dB or more
120dB or more
4.5-digit
FAST
0dB
55dB or more
3. CH-B DC Volt (DCV) VOAC7523H / 7520H only
Range
Resolution
Input Resistance
Accuracy*
4.5-digit
SLOW/MID
FAST
5V
100μV
CH-B:H to CH-B:L 10MW ± 3% CH-B:H to CH-A:L 5MW ± 3% CH-B:L to CH-A:L 5MW ± 3%
0.025+2
0.025+30
50V
1mV
0.025+8
300V
10mV
0.025+5
Max. input voltage:
± 300V, between CH-A L and CH-B ± 300V
Resolution and noise rejection
Resolution
Sample Rate
NMRR
CMRR
Isolation between CH-A and CH-B
4.5-digit
SLOW/MID
55dB or more
120dB or more
56dB or more
4.5-digit
FAST
0dB
55dB or more
4. AC Volt (ACV, DC+ACV) detection of True RMS
Up to 100kHz for VOAC7521H / 7520H
Range
Resolution
Measurement Range
Input Resistance
5.5-digit
SLOW
MID/FAST
500mV
1μV
15Hz to 300kHz
200Hz to 300kHz
less than approx. 1MW // 100pF
5V
10μV
50V
100μV
500V
1mV
45Hz to 100kHz
200Hz to 100kHz
750V
10mV
45Hz to 20kHz
200Hz to 20kHz
Accuracy: SLOW Sample (Sine wave Amplitude at 5% to 100% of fullscale of range)
Frequency
Accuracy*
15Hz to 45Hz
0.5+150
45Hz to 100Hz
0.25+150
100Hz to 30kHz
0.2+150
30kHz to 100kHz
0.5+300
100kHz to 300kHz
2.5+1000
Coefficient to input other than sine wave
Crest Factor
Crest Factor
1 to 1.5
1.5 to 2
2 to 3
15Hz to 30kHz
0.05%
0.15%
0.30%
30kHz to 300kHz
0.20%
-
-
Resnponse time
Sample Rate
Resolution
Reading Rate
Response Time
SLOW
5.5-digit
4 times/sec
less than 3 sec
MID/FAST
5.5-digit
20 times/sec
less than 2 sec
Max. input voltage: 780Vrms, ± 1100V DC (continuous)In the case of DC+ACV, 500 (less than 45Hz) or 300 (45Hz or higher) must be added to the value of Accuracy digit in above.Sample rate of FAST becomes the same values as MID (approx. 20 times/sec).
5. DC Current (DCA)
Range
Resolution
Accuracy*
Input Resistance
5.5-digit
4.5-digit
SLOW/MID
FAST
5mA
10nA
100nA
0.05+7
0.05+17
150W or less
50mA
100nA
1μA
15W or less
500mA
1μA
10μA
2W or less
10A
100μA
1mA
0.2+7
0.2+17
0.1W or less
Auto range is not available between 5mA to 500mA range and 10A range because of using different input terminals.Max. input current:500mA at 5mA to 500mA ranges (FUSE 0.5A/250V)10A at 10A range (FUSE 15A/250V)
6. AC Current (ACA, DC+ACA)
Range
Resolution
Measurement Range
Input Resistance
5.5-digit
SLOW/MID
FAST
5mA
10nA
15Hz to 5kHz
200Hz to 5kHz
150W or less
50mA
100nA
15W or less
500mA
1μA
45Hz to 5kHz
2W or less
10A
100μA
0.1W or less
Accuracy: SLOW Sample (Sine wave) amplitude at 5% to 100% of fullscale (10% to 100% for10A range)
Frequency
Accuracy*
Crest Factor
1 to 1.5
1.5 to 2
2 to 3
15Hz to 45Hz
1+200
0.05%
0.15%
0.30%
45Hz to 1kHz
0.4+200
1kHz to 5kHz
5.0+200
Response time
Sample Rate
Resolution
Reading Range
Response time
SLOW
5.5-digit
4 times/sec
less than 3 sec
MID/FAST
5.5-digit
20 times/sec
less than 2 sec
Max. input current:500mA for 5mA to 500mA ranges (FUSE 0.5A)10A for 10A range (FUSE 15A)DC Component on input current must be included in the Max. input current.In the case of 10A range at 45Hz to 1kHz, 0.3 must be added to %.In the case of DC+ACA, 500 (less than 45Hz) or 300 (45Hz or higher) must be added to the value of Accuracy in above.Sample rate of FAST becomes the same value as MID (approx. 20 times/sec).
Max. input voltage: ± 500V peakOpen circuit test voltage: 12V or lessThe accuracy at 50W to 5kW range are specified after zero compensation through the REL operation.Sample rate of FAST at 5MW to 500MW range becomes the same value as MID (approx. 20 times/sec).
8. Low-Power Resistance (2 WireW)
Range
Resolution
Accuracy*
Test Current
SLOW/MID/FAST
SLOW/MID
FAST
500W
10mW
0.1+5
0.1+15
approx. 1mA
5kW
0.1W
approx. 100μA
50kW
1W
approx. 10μA
500kW
10W
0.2+30
0.2+40
approx. 1μA
5MW
100W
0.2+30
approx. 100nA
50MW
1kW
1.5+30
1.5+30
approx. 10nA
Max. input voltage: ± 500V peakOpen circuit test voltage: 12V or lessThe accuracy at 500W to 5kW range are specified after zero compensation through the REL operation.Sample rate of FAST at 5MW to 500MW range becomes the same value as MID (approx. 20 times/sec).Indications are in 4.5 digits for SLOW, MID, and FAST.
9. Diode
Test Current
Measurement Range
Accuracy*
Open Circuit Test Voltave
Max. Input Voltave
approx. 1mA or 10mA
0.1mV to 5.0999V
0.014+13
12V or less
± 500V peak
10. Temperature
Thermocouple
Temperature Range to be Measured
Accuracy*
Resolution
Max. Input Voltave
R
-50°C to 0°C
0.2+70
0.1°C
± 500V peak
0°C to +100°C
0.2+50
+100°C to +1768°C
0.2+30
K(CA)
-200°C to -100°C
0.15+50
-100°C to 0°C
0.15+35
0°C to +1372°C
0.15+20
T(CC)
-200°C to -100°C
0.15+50
-100°C to 0°C
0.15+35
0°C to +400°C
0.15+20
J(IC)
-200°C to -100°C
0.15+50
-100°C to 0°C
0.15+35
0°C to +1200°C
0.15+20
E(CRC)
-200°C to -100°C
0.15+50
-100°C to 0°C
0.15+35
0°C to +1000°C
0.15+20
The above accuracy values do not include the thermocouple accuracy.±0.1°C/°C is added (for all thermocouples) with the operating ambient temperature of this product at 0°C to 18°C and 28°C to 50°C.accuracy is not specified. In the temperature range to be measured at -200°C or lower,The reference thermo electric force is calculated by the "broken line approximation" according to JIS C 1602-1995.If this product and the thermocouple are connected via a plug, an error for contact temperature compensation is added.
11. Frequency (AC couple, Crest Factor: less than 3)
Sample Rate
Reading Rate (Gate time)
Display Digits and Measurement Range
Accuracy*
SLOW
approx. 0.5 times/sec (1s)
6-digit
15.0000Hz to 1.00000MHz
0.02+2
MID
approx. 4 times/sec (100ms)
5-digit
15.000Hz to 1.0000MHz
FAST
approx. 10 times/sec (10ms)
4-digit
150.00Hz to 1.000MHz
AC couple: Crest factor <=3AUTO range of ACV must be used with input attenuator.Max. input voltage: 780 Vrms, ± 1100V peak