Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
IWATSU SY-5001A High-Frequency Bipolar Power Amplifier Dedicated Matching for SY-8264

IWATSU SY-5001A High-Frequency Bipolar Power Amplifier Dedicated Matching for SY-8264

Model:SY-8264+SY-600 10MHz high-frequency AC B-H analyzer      Country of Origin:Japan

Category:B-H Analyzer

Overview:

4-Quadrant Power Amplifier for use with IWATSU® SY-821x and SY-8264, 

DC – 5 MHz, ±150 V, ±6 A, 800 V/µs, GPIB-, USB- Interface

Features
Specifications
Application Notes
Functions & Configuration

The SY-5000A series linear high-frequency bipolar power amplifier is a world-leadingWideband precision power amplifier.

They are ideal for all applications requiring fast-changing signals under purely resistive and inductive loads. Two selectable operating voltage modes are provided, respectively for high-voltage/low-current and low-voltage/high-current applications. The SY-5001A additionally provides switchable gain factors and automatic offset control. When the load impedance is extremely low, please select the low operating voltage mode to reduce power loss and increase output current. The A model also has a built-in slew rate limiter to achieve more precise square wave signal output. These devices are equipped with temperature-controlled low-noise fans. Over-temperature protection, power loss calculation, and absolute current monitoring ensure comprehensive short-circuit and overload protection. The amplifier can be controlled via the operating elements on the front panel or fully remotely via USB. The SY-5001A can also be remotely controlled via GPIB with SCPI commands.

SY-5001A_2026-10-12_145220_627.png

High Speed Power Amplifier to use with B-H Analyzer

4-quadrant voltage amplifier

DC - 5 MHz, 800 V/μs


Main features:

- Amplifier output switch on/off

- Input jack: BNC

- Output jack: BNC

Broadband lab amplifier for ohmic and complex load

Optimized to drive cores under test (CUT) in IWATSU's B-H analyzers

- Stable with all inductive loads

High small signal bandwidth leads to small distortion

High slew rate with high voltage output at high frequencies

- Linear, low noise amplifier - no switching

Safety concept implies high impulse power without risk of damage

50 ohm input with switchable gains: 1, 5, 10, 30, 60

Robust DC-offset-zero with DC control, retriggered by user with switch

・ Rail voltage in two different levels to optimize and adjust low impedance loads

Rail voltage could be chosen by user via switch

- Fan with temperature control

Full remote control through USB or GPIB interface with SCPI protocol

Programmable current limit through remote control

Mains switch with 5 positions for 5 different voltage levels:

- Each voltage level sets the nominal voltage of 100 V/115 V/220 V/230 V/240 V

- operation is valid with a voltage tolerance of +/- 10%

・Firmware update via USB

LED controls for overload/over temperature/hardware error


SY-5001A_2026-10-12_144642_389.png

[1]:  ON / STANDBY Switch to turn the amplifier from standby to „ON“. Switch to standby with output off [3] only. 

[2]:  OUTPUT Power connector for output (±150V / ±10A max.). In „OFF“ state the output is switched to signal ground. 

[3]:  OUTPUT Switch to turn the output „ON“ or „OFF“. The switch lights up when the amplifier is  switched on. 

 [4]:  GAIN The gain switches are used to adjust the overall gain of the amplifier. The LED of the selected amplifi-                 cation factor lights up permanently. Changing the gain triggers an automatic offset adjustment.  

 [5]:  INPUT Signal input (±3V input voltage range), input impedance 50Ω, BNC. 

[6]:  GROUND SOCKET Protective earth connection. 

[7]:  OFFSET ZERO Switch to trigger, an DC offset adjustment. Lights up permanently after successful offset     adjustment, flashes at approx. 1 Hz in the event of an error during the offset adjustment.

 [8]:  OUTPUT VOLTAGE HIGH / LOW Switch to change the output voltage mode from HIGH (±150V) to   LOW (±75V) or vice versa. The LED lights up in HIGH voltage mode. Switch only when output is in idle  state, e.g. deactivated, for amplifier board firmware V1-05 or lower. 

[9]:   PROTECTION Lights up continuously at an overtemperature, flashes slowly (1 Hz) when exceeding maxi mum current limit or permissible power loss, and flashes quickly (3 Hz) at a hardware defect.

[10]   READY Lights up permanently when the amplifier is ready for operation


Applications:

1. High-frequency magnetic material loss analysis

2. High-frequency performance testing of inductive or capacitive loads

Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)