中文
WeChat
Add friend via WeChat QR code 18665876229

Scan the QR code on WeChat: 18665876229

Power device curve tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter Wide-temperature-range H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
IWATSU SY-5001A High-Frequency Bipolar Power Amplifier

IWATSU SY-5001A High-Frequency Bipolar Power Amplifier

Product model:SY-8264+SY-600 10MHz high-frequency AC B-H analyzer0 1 2 3 4 5 Place of origin:Japan

Category:Precision Bipolar Power Amplifier

Product overview:

4-Quadrant Power Amplifier for use with IWATSU® SY-821x and SY-8264, 

DC – 5 MHz, ±150 V, ±6 A, 800 V/µs, GPIB-, USB- Interface

Features
Specifications
Application Notes
Functions & Configuration

IWATSU Bipolar Power Supply recommended for B-H analyzers: LV mode DC to 1.4 MHz, ±64 V peak, ±5 A DC / ±6 A peak AC; HV mode DC to 600 kHz, ±150 V peak, ±2.5 A DC / ±5 A peak AC.

SY-5000 Series Bipolar Power Supplies for B-H Analyzers

Features

  • Recommended power supply for B-H analyzer
  • LV mode: DC to 1.4 MHz, ±64 V peak
  • HV mode: DC to 600 kHz, ±150 V peak
  • LV output ±5 A DC / ±6 A peak AC; HV output ±2.5 A DC / ±5 A peak AC

SY-5001A_2026-10-12_144642_389.png

[1]:  ON / STANDBY Switch to turn the amplifier from standby to „ON“. Switch to standby with output off [3] only. 

[2]:  OUTPUT Power connector for output (±150V / ±10A max.). In „OFF“ state the output is switched to signal ground. 

[3]:  OUTPUT Switch to turn the output „ON“ or „OFF“. The switch lights up when the amplifier is  switched on. 

 [4]:  GAIN The gain switches are used to adjust the overall gain of the amplifier. The LED of the selected amplifi-                 cation factor lights up permanently. Changing the gain triggers an automatic offset adjustment.  

 [5]:  INPUT Signal input (±3V input voltage range), input impedance 50Ω, BNC. 

[6]:  GROUND SOCKET Protective earth connection. 

[7]:  OFFSET ZERO Switch to trigger, an DC offset adjustment. Lights up permanently after successful offset     adjustment, flashes at approx. 1 Hz in the event of an error during the offset adjustment.

 [8]:  OUTPUT VOLTAGE HIGH / LOW Switch to change the output voltage mode from HIGH (±150V) to   LOW (±75V) or vice versa. The LED lights up in HIGH voltage mode. Switch only when output is in idle  state, e.g. deactivated, for amplifier board firmware V1-05 or lower. 

[9]:   PROTECTION Lights up continuously at an overtemperature, flashes slowly (1 Hz) when exceeding maxi mum current limit or permissible power loss, and flashes quickly (3 Hz) at a hardware defect.

[10]   READY Lights up permanently when the amplifier is ready for operation


Applications:

1. High-frequency magnetic material loss analysis

2. High-frequency performance testing of inductive or capacitive loads

Functions & Configuration

  • SY-5001
  • SY-5002
  • Some early models (DC~1.8MHz / 900kHz) have been discontinued