PMK LILCO® Wideband Current Transformer Series AC/DC Current Probes
Product model:13E0050/13G0050/13W0050/13E0100/13G0100/13W0100/13E0200/13G0200/13W0200/13E0500/13G0500/13W05000 1 2 3 4 5 Place of origin:Germany
Category:AC/DC Current Probe
Product overview:The LILCO® series of wideband current transformers covers bandwidths from mHz to >60 MHz and input currents from mA to 25 kA, enabling high-precision wideband AC current measurement for a wide range of measurement scenarios. Electrical shielding between input and output reduces the influence of external electromagnetic fields; galvanic isolation between input and output makes them suitable for applications with large potential differences or ground loops. The BNC output can be connected via standard 50Ω coaxial cable to oscilloscopes, digitizers, network analyzers, spectrum analyzers, power analyzers, multimeters, and other equipment. The model number includes the inner diameter information (e.g., 13=13 mm, 58=58 mm, 89=89 mm). ATT10BNCS attenuator...
The LILCO® series of wideband current transformers covers bandwidths from mHz to >60 MHz and input currents from mA to 25 kA, enabling high-precision wideband AC current measurement for a wide range of measurement scenarios. Electrical shielding between input and output reduces the influence of external electromagnetic fields; galvanic isolation between input and output makes them suitable for applications with large potential differences or ground loops. The BNC output can be connected via standard 50Ω coaxial cable to oscilloscopes, digitizers, network analyzers, spectrum analyzers, power analyzers, multimeters, and other equipment. The model numbers include the inner diameter information (e.g., 13=13 mm, 58=58 mm, 89=89 mm). The ATT10BNCS attenuator further improves low-frequency performance and I·t capability while maintaining high-frequency performance. Each unit is supplied with a factory calibration certificate.
Product Features
Bandwidth mHz ~ >60 MHz (up to 85 MHz for some models)
Input current mA ~ 25 kA (peak up to 25000 A)
Galvanic isolation, suitable for ground loop/large potential difference scenarios
Electrical shielding between input/output, resistant to external magnetic field interference
BNC output, compatible with 50Ω measurement equipment
Model numbers include inner diameter information: 13/26/58/89 mm
Each unit supplied with a factory calibration certificate
ATT10BNCS attenuator further optimizes low-frequency performance
Parameter
Specification
Upper bandwidth (-3dB)
1 MHz ~ 85 MHz (by model, up to 85 MHz)
Lower bandwidth (-3dB)
0.04 Hz ~ 1400 Hz (by model, down to 0.04 Hz)
Sensitivity (output)
0.01 ~ 1 V/A (by model)
Maximum peak current
Up to 25000 A (58E0020 / 58EH010, etc.); minimum 500 A
Maximum RMS current
7 A ~ 500 A (by model)
Rise time
7 ns ~ 200 ns (by model)
Inner diameter
13 mm / 26 mm / 58 mm / 89 mm (indicated in model number)
ATT10BNCS attenuator
20 dB, ±0.25 dB, DC~50 MHz, 50Ω±1%, input power 2.25 W
Application Notes
Wideband AC current measurement
Power electronics pulse/high-current measurement
Isolated measurement in ground loop/high potential difference scenarios
Matching with oscilloscopes, digitizers, network/spectrum/power analyzers
Current transformer calibration and comparison
Functions & Configuration
13 series (13 mm inner diameter): 13E/G/W 0050/0100/0200/0500/1000
58 series (58 mm inner diameter): 58E/M/H sensitivity models
89 series (89 mm inner diameter): 89M0100
Model suffixes: E (economy) / G / W / M / H correspond to different droop, I·t and sensitivity
Accessory: ATT10BNCS attenuator (20 dB)