Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Technical Services & Solutions

Technical support and after sales service

Technical Services & Solutions

What are the "transmission characteristics" of a circuit or system?

Published: 2021-05-29 Views: 次

What Are "Transfer Characteristics"?


What Are Transfer Characteristics?


"Transfer characteristics" describe the conditions or states under which a device under test (DUT) transfers (transmits, conducts) physical quantities such as electricity, heat, or vibration. They are key parameters for understanding how a DUT behaves, responds, and reacts.





For an audio amplifier, this is equivalent to the gain. For a temperature sensor, the relationship between heat (input) and the electrical signal (output) is called the transfer characteristic.
Electrical impedance is the ratio of voltage to current, so if you know the input current and the output voltage, impedance characteristics can also be considered a type of transfer characteristic in the broad sense.


How Are Transfer Characteristics Measured?


Because physical quantities such as heat and vibration are difficult to handle directly, they are converted by transducers or sensors into electrical signals that are easier to process, and then measured. In practice, it is not just the simple output-to-input ratio that matters—response speed and frequency response characteristics are also important parameters. Transfer characteristics that focus on response speed are called "time-domain transfer characteristics"; those that focus on frequency response are called "frequency-domain transfer characteristics."


Time-Domain Transfer Characteristics


Waveforms are easy to display graphically, but numerical management is difficult
 ----> Instrument used: observe waveforms with an oscilloscope


Frequency-Domain Transfer Characteristics


Instruments are often more complex, but precise measurement suited to numerical management is possible
 ----> Instruments used: frequency response analyzer (FRA), FFT (fast Fourier transform) analyzer + oscillator
What Instruments Are Used to Measure Transfer Characteristics?


Instruments for Measuring Transfer Characteristics


fft●FFT (fast Fourier transform) analyzer with built-in signal source (FFT servo analyzer)

fra●Frequency response analyzer (Frequency Response Analyzer)


Both instruments have a built-in signal source for measurement. They digitize and compute (Fourier transform) the signals before and after the circuit under test (input and output), then determine the gain and phase to measure transfer characteristics. Below, we compare and examine the various related instruments.


Different Measurement Principles

fftThe measurement signals (built-in signal source) used in the FFT (fast Fourier transform) method include pulses, random noise, and swept markers. Each of these contains broad frequency components (a wide spectrum).

fraThe signal source used for FRA measurement is a sine wave at a fixed frequency. To measure transfer characteristics over a wide frequency range, the frequency is changed slightly for each measurement (frequency sweep), and measurements are repeated.


Measurement Accuracy


The FFT method measures using a fixed range. As a result, small signal components can be buried in noise, increasing measurement error.
The FRA method, by contrast, measures only one frequency component at a time, so it can automatically set the optimum range for each measurement. In other words, when measuring weak signals, it increases sensitivity, enabling analysis with a good signal-to-noise ratio (good measurement accuracy).


Frequency Resolution Can Be Set Freely


In the FFT method, the analysis results are level values at equal intervals on the frequency axis. So if the frequency axis is plotted logarithmically, data becomes sparse at low frequencies and extremely dense at high frequencies.
In contrast, the FRA method allows measurement at any arbitrary frequency points, so measurement data can also be equally spaced on a logarithmic axis.
Comparison Itemfrafft
Signal sourceSine wave
Pulse or noise, swept markers, etc.
Possibility of saturating the system with the measurement signalSafe and reliable
(low risk of saturation)
Care required during measurement
(high risk of saturation)
Dynamic rangeVery wide
Automatic range switching
Narrow
Measured on a single range
Frequency resolution
(distribution of measurement points)
Arbitrary (fine or coarse) / logarithmic distribution with respect to frequency (distribution when frequency is plotted logarithmically)Determined by sampling / uniform distribution with respect to frequency (if frequency is plotted logarithmically, points are sparser at the low end than at the high end)
Injection of the measurement signalEasy (isolated signal source)Requires careful consideration
Window function settingNot requiredRequired (select from several options)
Measurement procedure1. Enter the frequency range and resolution of the DUT (arbitrary)
2. Set the signal level and number of integrations