UKAS ISO17025:2017 calibration accreditation (power)
In 2013, Newtons4th UK obtained UKASISO17025:2017calibration laboratory accreditation for voltage, current, power, phase, harmonics and flicker. Our motivation for obtaining this accreditation was a commitment to the highest level of metrology in our field of activity and a desire to provide an accredited calibration certificate with every new power analyzer we ship. This was a first in our industry and provides users of N4L power analyzers with a higher level of standard calibration than any other power analyzer manufacturer. Significant time and engineering effort was also spent implementing complex IEC61000-3-2, IEC61000-3-3, IEC61000-3-11 and IEC61000-3-12 harmonics and flicker calibration facilities. This additional accreditation was also recognized, making N4L the first power analyzer manufacturer to offer power analyzer products that meet the measurement standards currently defined by the IEC61000 harmonics and flicker standards. Our accreditation schedule can be viewed on thethis linkUKAS website N4L products combine market-leading accuracy with exceptional stability, giving users confidence in the long-term integrity of their measurements. While we recommend recalibration every 12 months, stability over time and a conservative approach to product specifications allow our products to remain within specification for longer periods. This is demonstrated by many N4L customers who, based on theirISO9001accreditation work, are able to select a 24-month calibration period for the N4L products they own. In addition to providing voltage, current, phase and power calibration up to 850Hz and calorimetric power up to 2MHz,UKAS ISO:17025In addition to accreditation, we have developed a proprietary high-frequency multi-channel signal generator called ACC-IV (Automatic Calibration Controller 4). Combined with custom-designed amplifiers, ACC-IV provides higher signal-level high-frequency voltage and current sources than commercially available calibrators, and gives N4L a way to calibrate our power analyzers over a wider frequency range than any other company. The term "calibration" is commonly used for measuring instruments but is surprisingly misunderstood. Common misconceptions include believing that a unit will be more accurate after calibration, when in fact most traditional calibrations do not change accuracy at all, or that any ISO17025 "accredited" calibration will provide a greater accuracy guarantee than an ISO17025 "traceable" calibration, which is often incorrect. Since N4L offers a wide range of calibration options, including ISO17025 accredited calibration, with an accreditation schedule broader than most power metrology laboratories, we can fairly consider these options. In the document linked below, we summarize the fundamentals of calibration and the benefits of measurement optimization for users during any calibration process. Power measurement calibration – what makes N4L different?, PDF 371kb The exceptional detail and accuracy of our calibrations are achieved through unique calibration hardware combined with an absolute commitment to best metrology practice. This includes standard calibration, calibrating more than 200 calibration points at different levels and frequencies against the adjustment points we use for measurement optimization, thereby ensuring the linearity of the instrument under test and the integrity of the calibration. Investment in 10 fully automated test systems enables N4L to provide the highest level of calibration for every power analyzer we supply. Summary: Every power analyzer comes with two calibration certificates 1. ISO17025 UKAS-accredited voltage, current, phase, power calibration (including low power for EN50564 and Energy Star) and PF up to 850 Hz. 2. Broadband calibration certificates traceable to national standards, covering up to 500kHz (PPA500), 1MHz (PPA1500/PPA3500) and 2MHz (PPA4500/PPA5500)。 Optional calibration: 1.ISO17025 UKASAccreditedHarmonics and flickerCalibration conforms toIEC61000-4-7 / IEC61000-4-15 2. PPA5500-HFISO17025 UKASCalorimetric certificates are available on request. For more information, please contact us viasupport@newtons4th.com Our comprehensive calibration procedures are unmatched in our industry*, and we believe our power analyzers deliver the highest broadband performance on the market. *According to N4L research 2014
UKAS (ISO17025) Accreditation Schedule Signal Amplitude Frequency range Voltage Sine Amplitude 1V to 1008V 16 Hz to 850 Hz Voltage Harmonic Amplitude 0V to 302V 16 Hz to 6kHz Current sine wave amplitude 100mA to 48A 16 Hz to 850 Hz Current harmonic amplitude 0A to 15A 16 Hz to 6kHz Current-Voltage Phase Angle -180° to +180° 16 Hz to 850 Hz Apparent power (VA product) 100mVA to 48.4kVA 16 Hz to 850 Hz AC power source (reference source) 0W to 48.4kW 16 Hz to 850 Hz AC power source (calorimetric) (added in 2017) 1W to 5W 45 Hz to 2 MHz Impedance Network Calibration (compliant with IEC61000) 33 milliohms to 400 ohms 45 Hz to 850 Hz Current harmonic amplitude per IEC61000-4-7 0A to 6A 16 Hz to 6kHz Flicker per IEC61000-4-15 Pin (sine modulation) Compliant with IEC61000 standards Pin (rectangular modulation) Pst Frequency variation Distorted voltage with multiple zero crossings Harmonics with sidebands Phase jumps Rectangular with duty cycle variation B (2) The N4L calibration philosophy
ACCIV standard calibration (using UKAS traceable instruments) Signal Amplitude Frequency range Voltage Amplitude +/-250uVpk to +/-400Vpk DC to 100kHz
Linearity down to +/-10Vpk 100kHz
to 2MHzDC to 2MHz Current amplitude +/-1mApk to +/-5Apk DC to 100kHz
+/-300mApk to 100kHz to 2MHzDC to 2MHz Related documents:
Technical Note 002 – The importance of ranging techniques and calibrationPDF, 324kb
Technical Note 003 – Closed-Loop CalorimetryPDF, 2,418kb
ISO 9000 Certificate (valid until 2023)PDF, 240kb
UKAS (ISO17025) Accreditation CertificatePDF, 643kb
Accreditation schedule link:https://www.ukas.com/wp-content/uploads/schedule_uploads/00001/7949Calibration%20Single.pdf
N4L Calibration Traceability Ladder link:N4L 17025 Calibration Traceability 2017PDF, 492kb
Power measurement calibration – what makes N4L differentPDF, 371kb