Impedance Analyzer/LCR Meter
Precision Impedance Analyzer - 10uHz to 50MHz
Quickly compare the complete impedance analyzer range
When used withPSM Series Frequency Response AnalyzerWhen used together, the N4L impedance analysis interface provides a measurement solution for many impedance analysis applications. The most suitable interface for a particular application will depend on the nominal impedance of the sample or device under test and the measurement frequency. N4L will be happy to discuss the best solution for any application. N4L has developed the impedance analyzer with the widest measurement range on the market. N4L's range spans from 1mΩ to 1TΩ, capable of meeting a wide range of industry needs, including electronic component analysis, power electronics system analysis, electrochemical material analysis, electrical material analysis, and more. From the budget LCR active head solution covering up to 100MΩ to the top-tier IAI2 covering more than 11 decades of impedance between 1mΩ and 500MΩ with excellent accuracy. Reasons to choose the N4L impedance analyzer The PSM series impedance analyzers can be used as standalone test instruments, with measurements made using the instrument keypad and viewed on the LCD/TFT display. Alternatively, users can utilize our PSMComm2 software program for remote control and data acquisition. Users can also write their own software control programs, such as in C, C#, or VBA. As a result, the PSM can be integrated into larger test systems. LabVIEW drivers are also available if needed (on ourSupported components), helping LabVIEW developers quickly integrate the PSM/IAI impedance analyzer into their test systems. All software is available through our websiteFree download。 Impedance analyzers can be used in many ways, from simple LCR measurements of discrete components to material analysis of insulators and electrochemical solutions. Determine the ESR of filter capacitors used in power electronic circuits across the bias voltage range Determine capacitance at different bias voltages Determine choke inductance at various bias currents Determine the input/output impedance of any circuit or system Evaluate the impedance of piezoelectric circuits Automated LCR measurement of discrete components within an integrated test system Insulation resistance characterization Transformer winding inductance analysis Analysis of the concrete curing process Characteristics of nylon bushings Rubber Mount Conductivity Electrochemical analysis Fruit and vegetable ripeness analysis through impedance measurement Medical and bioimpedance analysis Paint film finish analysis through impedance measurement Bonding impedance evaluation Electroplating analysis Impedance spectroscopy as a tool for monitoring moisture absorption in building composites during service.Grammatikos, S., A. Bauer, R. J. Evenden, M. Jones, R. G.. (2018), Elsevier. Battery Characterization Methods for Electric Vehicles. Fernandes, A., G. Azarin, S., M. (2020), University of Oviedo, Spain. Biomaterial Scaffolds as a Platform for Localized Therapy Against Disseminated Cancer Cells.Pelez, F. (2018), University of Minnesota, USA. 将Conformal printing of graphene onto 3D surfaces of arbitrary shape for single-layer and multilayer devices.Leonard, Wu Weiwen, T. Xiaoxi, Hu Zhiqiang, G. Makadam, N. Um, D. Wu, T-C. Moal, F. Jones, C. Hasan, T. (2019), University of Cambridge, UK. Impedance Spectroscopy as a Tool for Monitoring Moisture Absorption in Building Composites During Service。Niyomsatian, K. (2018), IEEE, Elsevier. Study on iron loss characteristics in amorphous rings excited by silicon- and gallium nitride-based inverters.Yao, A. Tsukada, K. Fujisaki, K. (2017), IEEJ Modeling and Feedback Control of LLC Resonant Converters at High Switching Frequencies.Parker, HP Ronger. J-H. (2016), Journal of Power Electronics. Scalable, self-aligned printing of flexible graphene micro-supercapacitors. Hyun, W, J. Secor, E, B. Kim, C, H. Hersam, M, C. Francis, L, F. Frisbie, D, C. (2017), Advanced Energy Materials. Detection of damage and repair in cement mortar using electromechanical impedance.Taha, H. Ball, R, J. Paine, K. (2019), Journal of Materials. Revisiting Synchronized Charge Extraction (SECE) in Impedance-Based Piezoelectric Energy Harvesting viaBroadband Impedance Spectroscopy from 1 mHz to 10 MHz Using a Combination of Four-Electrode and Two-Electrode Methods.Folkman, Jan and Kritzsch, Norbert. (2015) Electric Vehicle Power System Modeling.Widdeck, P. (2022)



Basic accuracy 0.2% 0.1% 0.1% 0.01 dB Phase accuracy 0.454 0.454 0.454 0.454 Frequency range 10uHz ~ 5MHz 10uHz ~ 35MHz (PSM1700 - 1MHz) 10uHz ~ 50MHz 10uHz ~ 100kHz Impedance Analyzer Measurement Range

Precise LCR measurements using the PSM+IAI series impedance analyzers
Wide frequency range
Wide impedance range
High phase accuracy
High performance-to-cost ratio
Excellent impedance accuracy
Flexible functions
Remote control capability
Full Graphical Display
High-selectivity DFT analysis
Automatic range switchingBenchtop or PC interface

Different uses of N4L impedance analyzers

Electrical/electronic engineering
Mechanical engineering and material analysis

Research Papers Featuring PSM+IAI
Technical Support
Feedback