Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
NF ZM2371/2372/2376 ALC (Automatic Level Control) 100KHZ LCR Meter Japan Circuit Design

NF ZM2371/2372/2376 ALC (Automatic Level Control) 100KHZ LCR Meter Japan Circuit Design

Model:ZM2371/2372/2376      Country of Origin:Japan

Category:High-Frequency LCR Meter

Overview:

ZM2371

Basic accuracy 0.08%, frequency range 1mHz to 5.5MHz, measurement speed as fast as 2ms, contact check, low capacitance check.

ZM2372

Basic accuracy 0.08%, frequency range 1mHz to 100kHz, measurement speed as fast as 2ms, 4-terminal contact check function, handler interface.

ZM2376

Basic accuracy 0.08%, frequency range 1mHz to 5.5MHz, measurement speed as fast as 2ms, contact check, low capacitance check.


Features
Specifications
Application Notes
Functions & Configuration

 

Wide frequency measurement range and high-resolution settings

The ZM2371 and ZM2372 cover a measurement frequency range from 1 mHz to 100 kHz and offer 5-digit resolution. The ZM2376 covers a measurement frequency range from 1 mHz to 5.5 MHz and offers 6-digit resolution. This product is not only suitable for measuring general electronic products, but can also be used to evaluate the impedance characteristics of batteries and other materials.


Highly repeatable measurement results

The test results of this product are the results of testing the same test object 200 times under the same test conditions. The deviation of the ZM2372 test results is approximately below 0.01%, while the ZM2376 is even better. Highly repeatable measurement results are extremely important for an impedance analyzer.

- Measuring a 1 nF capacitor
Measurement conditions (time: 5 ms, frequency: 100 kHz, signal level: 1 V)
Deviation of 200 measurement results

ZM2736ZM2732
Discharge protection function

When using general-purpose measuring instruments, an electrolytic capacitor that has stored charge will discharge once connected, and the input circuit is very likely to be damaged. The ZM series' discharge protection function protects the input circuit from being damaged by this energy (up to 4 J). Therefore, if a component that has stored charge is accidentally connected during measurement, accidents can be prevented.


Wide measurement signal level range and ALC function

The measurement signal level from 10 mVrms to 5 Vrms / 1 μArms to 200 mArms can be set with 3-digit resolution. In addition, the ALC (automatic level control) function enables constant-voltage/constant-current driving, so the device can be driven with a stable drive signal that takes into account the voltage/current dependence of the sample, enabling highly reproducible measurements.


Fast measurement

The measurement time can be switched among 5 levels: RAP (Rapid), FAST, MED (Medium), SLOW, and VSLO (Very Slow). Selecting RAP enables fast measurement of 2 ms (1 kHz/1 MHz) and 10 ms (120 Hz). A fast, high-precision LCR meter helps improve the measurement efficiency of production lines and automatic inspection equipment.


High precision

Achieves high-precision measurement with basic accuracy of 0.08% and display resolution of up to 6 digits. Reliable measurement is indispensable for improving product performance and quality, from the development of cutting-edge devices to component sorting on inspection lines.


DC bias voltage

The built-in DC bias power supply of the ZM2371 and ZM2372 is 0 to +2.5 V, and that of the ZM2376 is 0 to +5 V. This function makes it possible to measure polar components such as electrolytic capacitors. With the ZM2376, impedance can be measured in a way that cancels out the DC voltage of the battery.

In addition, for larger DC voltages, a DC bias adapter is available as an option. Using an external DC power supply, a DC bias voltage of up to ±40 V can be applied to the device under test, so the dependence of large-capacity multilayer ceramic capacitors, etc. can also be measured.

zm_image
DC resistance (DCR) measurement

Can measure the DC resistance of the winding resistance of coils and transformers. The inductance can be displayed as the primary parameter and the DC resistance measurement value as the secondary parameter at the same time.

                                   

                                    Plenty of functions for production lines too!


Contact check function


● ZM2372


4-terminal contact check

To prevent erroneous measurement or incorrect sorting caused by poor contact between the measurement tips and components, the ZM2372 uses 4 measurement terminals to perform contact check judgment, thereby eliminating defective products.

(Additional time for contact check: 4 ms)


image.png


● ZM2376




Contact check, low capacitance check

Detects abnormally low capacitance as well as voltage and current, and can detect poor contact without additional time.



Trigger circuit synchronized drive

A function that can drive the sample only during contact.
It can reduce contact damage caused by attaching and detaching the sample when measuring large-capacity capacitors. For samples whose measurement history characteristics are measured in a short time, the measured values will show large errors. If trigger circuit synchronized drive is used, the drive signal applied to each sample and the timing and phase relationship of the acquired signal are fixed, which can suppress errors in measured values and greatly shorten the measurement time.


Deviation display

By presetting the display value of the measured component, the deviation and deviation % from the preset value can be displayed. It can be applied to pass/fail judgment of specification values for component tolerances and temperature characteristic tests, etc.


Comparator

The primary parameter can be divided into up to 14* BIN categories, and the secondary parameter can sort the measurement results against one set of configured upper/lower limits. Measured values can be sorted by deviation or deviation %, and the judgment result is output via the handler interface*. In addition, depending on the judgment result, a beep sound may be emitted.
In remote control, using the limit judgment function, the upper and lower limits (one set each) of the primary and secondary parameters can also be judged.
*ZM2371: Up to 9 categories, no handler interface equipped.


Composite measurement (ZM 2376)

Composite measurement is a function that can specify measurement conditions for up to 32 steps for one sample and perform comprehensive pass/fail judgment. The measurement frequency, measurement signal level, internal DC bias, measurement parameters, etc. can be set for each step, and measurement and limit judgment are performed for one set of upper/lower limits of the primary parameter and one set of upper/lower limits of the secondary parameter.
*A function unique to the ZM2376.

+

Interfaces


Various interfaces for remote control are standard equipment. Production line integration and automatic inspection systems, etc. can be supported without adding optional items.

Item

ZM2371

ZM2372

ZM2376

Measurement parameters

  Primary parameter: |Z|、|Y|、 L、 C、 R、 G
  Secondary parameter: Q、 D、 θ、 X、 B、 Rs、 Rp、 G、 Lp、 Rdc

Measurement frequency

1 mHz~100 kHz

1 mHz~5.5 MHz

Basic accuracy

0.08 %

Measurement signal level

10mVrms~5Vrms、1μArms~200mArms

InternalDCBias

0~+2.5V

0~+5V

Measurement time

1kHz

Fastest2ms

1MHz

—

—

Fastest2ms

Constant voltage/
Constant current drive (ALC)

○

○

○

Contact detection

—

○(4Terminal)

○

Low capacitance detection

—

—

○

Comparator

○(9Category)

○(14Category)

○(14Category)

Composite measurement

—

—

○(32steps)

Handler interface

—

○

○


 Applications


Measurement using long cables / temperature test chamber


The ZM series features a compensation function that suppresses the effects of cabling. In the following measurement examples, the measurement results differ little whether 1m, 2m, or 4m cables are used. In measurements using a temperature test chamber, the cables between the measuring instrument and the device under test are very long and thin, yet accurate measurement results can still be obtained.




▲ Example of inductance measurement (cable length 1m, 2m, 4m)



Fast measurement of lithium-ion battery impedance.


The internal DC bias voltage of the ZM2376 can be set to a maximum of +5V, so it can measure lithium-ion batteries (single cells) with an electromotive force exceeding 3V.

In addition, measurement can start from a low frequency of 1mHz, so the internal impedance of the battery can be evaluated in detail.


Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)

Inquiry Type: Message