Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters
Products
{

{"translation": "Lianxun S3030F High-Voltage Source Measure Unit with ±3500V, ±120mA output capability"}

Model:S3030F      Country of Origin:China

Category:SMU Source Measure Unit

Overview:

The S3030F from Lianxun is a compact, cost-effective single-channel high-voltage, high-power source/measure unit (SMU) capable of sourcing and measuring voltage and current simultaneously. It delivers up to ±3500 V, ±120 mA (DC), 10 GΩ, and 180 W output, making it well suited to a wide range of testing and research applications including power semiconductor characterization, GaN and SiC evaluation, composite materials, and high-voltage leakage current measurements. The S3030F supports conventional SMU SCPI commands, making migration of existing test code quick and easy. It also supports multi-unit synchronization and can be integrated into production test systems to improve test throughput and reduce cost. 

Features
Specifications
Application Notes
Functions & Configuration

3030F.png

S3030F High-Voltage, High-Precision Source Measure Unit (SMU)

The iTest S3030F is a compact, cost-effective single-channel high-voltage, high-power source/measure unit capable of sourcing and measuring voltage and current simultaneously. It delivers up to ±3500 V, ±120 mA (DC), 10 GΩ, and 180 W output, making it well suited to a wide range of testing and research applications including power semiconductor characterization, GaN and SiC evaluation, composite materials, and high-voltage leakage current measurements. The S3030F supports conventional SMU SCPI commands, making test code migration quick and easy. It also supports multi-unit synchronization and can be integrated into production test systems to improve test throughput and reduce cost. 


S3030F High-Voltage, High-Precision Source Measure Unit (SMU) Voltage Source Specifications:

Voltage Setting Accuracy

Range

Setting Resolution

Accuracy (1 year)

±(% of reading + offset)

Typical Noise (RMS)

0.1 Hz–10 Hz

±3500 V

40 mV

0.02% + 600 mV

50 mV

±2500 V

30 mV

0.02% + 450 mV

40 mV

±1500 V

20 mV

0.02% + 300 mV

25 mV

±600 V

7 mV

0.02% + 120 mV

10 mV

±200 V

3 mV

0.02% + 40 mV

3 mV

Temperature coefficient

±(0.15 × accuracy specification)/°C (0℃–18℃, 28℃–50℃)

Settling time

< 5 mS (typical)

Overshoot

< ±1% (typical, Normal, step from 10% to 90% of range, full-scale point, resistive load test)

Noise 10 Hz–20 MHz

1500 V voltage source, 120 mA resistive load, < 200 mV RMS


S3030F High-Voltage High-Precision Source Measure Unit (SMU) current source specifications:

Current setting accuracy

Range

Setting resolution

Accuracy (1 year)

±(% reading + offset)

Typical noise (RMS) 0.1Hz-10Hz

±120 mA1

3 uA

0.02% + 35 μA

120 uA

±20 mA

400 nA

0.02% + 15 μA

20 uA

±10 mA

200 nA

0.02% + 3 uA

10 uA

±1 mA

20 nA

0.02% + 300 nA

1 uA

±100 μA

2 nA

0.02% + 30 nA

100 nA

±10 μA

200 pA

0.03% + 5 nA

10 nA

±1 μA

20 pA

0.03% + 1 nA

1 nA

±100 nA

2 pA

0.2% +100 pA+Vo x 100 fA

100 pA

±10 nA

200 fA

0.2% + 10 pA+ Vo x 10 fA

10 pA

±1 nA

20 fA

0.2% + 5 pA+ Vo x 1 fA

1 pA

Temperature coefficient

±(0.15 × accuracy specification)/°C (0℃-18℃,28℃-50℃)

settling time

<10 ms (typical)

Overshoot

<±1% (typical, Normal, step is 10% to 90% of range, full-scale point, resistive load test)

1. The 120mA range only supports voltage ranges of 1500V and below

S3030F High-Voltage High-Precision SourceMeter SMU Voltmeter Specifications:

Voltage measurement accuracy

Range

Display resolution

Accuracy (1 year) ±(% reading + offset)

±3500 V

1 mV

0.02%+600 mV

±2500 V

1mV

0.02%+450 mV

±1500 V

1 mV

0.02%+300 mV

±600 V

100 uV

0.02%+120 mV

±200 V

100 uV

0.02%+40 mV

Temperature coefficient

±(0.15 × accuracy specification)/°C (0℃-18℃,28℃-50℃)

S3030F high-voltage high-precision SourceMeter SMU ammeter specifications:



Current measurement accuracy

Range

Display resolution

accuracy (1 year)  ±(% reading + offset)

±120 mA1

100 nA

0.02% + 35 μA

±20 mA

10 nA

0.02% + 15 μA

±10 mA

10 nA

0.02% + 3 uA

±1 mA

1 nA

0.02% + 300 nA

±100 μA

100 pA

0.02% + 30 nA

±10 μA

10 pA

0.03% + 5 nA

±1 μA

1 pA

0.03% + 1 nA

±100 nA

100 fA

0.2% +100 pA+Vo x 100 fA

±10 nA

10 fA

0.2% + 10 pA+ Vo x 10 fA

±1 nA

1 fA

0.2% + 5 pA+ Vo x 1 fA

Temperature coefficient

±(0.15 × accuracy specification)/°C (0℃-18℃,28℃-50℃)

1. The 120mA range only supports voltage ranges of 1500V and below

S3030F high-voltage high-precision SourceMeter SMU ohmmeter specifications(4线)

Resistance measurement accuracy

Range

Display resolution

default measurement current

Typical accuracy (1 year)

±(% reading + offset)

100 Ω

100 μΩ

100 mA

0.075% + 400 mΩ

1 kΩ

1 mΩ

10 mA

0.07% + 4 Ω

10 kΩ

10 mΩ

1 mA

0.07% + 40 Ω

100 kΩ

100 mΩ

100 μA

0.07% + 400 Ω

1 MΩ

1 Ω

10 μA

0.10% + 4 kΩ

10 MΩ

10 Ω

1 μA

0.15% + 40 kΩ

100 MΩ

100 Ω

100 nA

0.32% + 400 kΩ

1 GΩ

1 KΩ

10 nA

0.32% + 4 MΩ

10 GΩ

10 KΩ

1 nA

0.72% + 40 MΩ

Temperature coefficient

±(0.15 × accuracy specification)/℃ (0℃-18℃, 28℃-50℃)

Manual current source resistance measurement

(four-wire)

Total error = measured voltage / current source set current = resistance reading x (voltage source range gain error percentage + ammeter range gain error percentage + current source range offset error / set current) + (voltage source range offset error / set current value)

Example: current source set current=10mA  voltage measurement range=200V

Total error=(0.02%+0.02%+3μA/10mA)+(40mV/10mA)

≈0.07%+4Ω

Note: measured voltage=default measured current*measured resistance value≤10.5V