Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
PEM CWT-LF Low-Frequency AC Probe 0.06KA-30KA Rogowski Coil High-Frequency AC Probe

PEM CWT-LF Low-Frequency AC Probe 0.06KA-30KA Rogowski Coil High-Frequency AC Probe

Model:CWT LFSeries      Country of Origin:UK

Category:AC/DC Current Probe

Overview:

The CWT LF series current probes are primarily conversion tools designed to solve your low-frequency current measurement problems.

It features: measurement of very small currents at 50/60 Hz; measurement of very small phase shifts in sine waves; the CWT's standard and miniature sensing loops measure current long-pulse attenuation; the CWT LF series is available with standard-length and mini-length sensing coils.

Features
Specifications
Application Notes
Functions & Configuration

PEM Rogowski coils, as the world's leading wideband high-current sensors, are current sensors developed and provided by PEMUK (UK) based on Rogowski coil technology to meet various application requirements.

PEM Rogowski coils cover current measurement from 0.1Hz to over 30MHz, and from 15mA to over 3MA. PEM Rogowski coils are divided by application scenario into the CWT series for wideband high current, the RCT series for industrial monitoring, the LFR series for low frequency with high cost-effectiveness, the CMC series dedicated to motor common-mode noise measurement, and the DCFlex series for transient DC measurement.

The CWT series Rogowski coils can be customized to measure pulsed and continuous current signals of over 2MA (2000KA) at maximum. The CMC common-mode Rogowski coils are dedicated to testing high-frequency common-mode noise of motor and generator bearings in the electromechanical industry.



Key Features:

●Measurement range: 1A~300,000A

●Typical bandwidth: 0.1Hz~6MHz

●Thin, flexible high-performance sensing loop: (can be customized to any length: standard or miniature coils)

●Near-zero interference: during measurement, the actual load current is only a few picohenries

●Easily connected to the actual measurement object

●Very small 'attenuation' value

●CE mark

●Instantaneous voltage output is ±6V peak-to-peak, which can be directly connected to oscilloscopes, data acquisition devices, digital voltmeters and power recording devices, and can also be used as a trigger input

1. Standard length


Model

Sensitivity(mV/A)

峰      值

最  大
噪  声 (mVpk-pk)

Attenuation characteristics
(%/ms)

Low frequency  Bandwidth
(Hz)

50Hz时  Phase lead (deg)

High-frequency bandwidth
(MHz)

电 流
(KA)

di/dt
(KA/µs)

Cable length300
(mm)

Cable length700
(mm)

CWT03LF

100.0

0.06

0.4

15.0

4.6

5.1

8.3

6.5

3.0

CWT06LF

50.0

0.12

0.8

15.0

2.3

2.6

4.2

6.5

3.0

CWT1 LF

20.0

0.3

2.0

15.0

1.0

1.0

1.8

6.5

3.0

CWT3 LF

10.0

0.6

4.0

15.0

0.5

0.55

0.85

6.5

3.0

CWT6 LF

5.0

1.2

8.0

15.0

0.25

0.27

0.45

6.5

3.0

CWT15LF

2.0

3.0

11.0

15.0

0.1

0.11

0.18

6.5

3.0

CWT30LF

1.0

6.0

11.0

15.0

0.05

0.055

0.09

6.5

3.0

CWT60LF

0.5

12.0

11.0

15.0

0.025

0.022

0.045

6.5

3.0

CWT150LF

0.2

30.0

11.0

15.0

0.01

0.011

0.018

6.5

3.0

CWT300LF

0.1

60.0

11.0

10.0

0.007

0.008

0.012

6.5

3.0

CWT600LF

0.05

120.0

11.0

5.0

0.007

0.008

0.012

6.5

3.0

CWT1500LF

0.02

300.0

11.0

4.0

0.007

0.008

0.012

10.0

5.0

2. Miniature length


Model

Sensitivity(mV/A)

峰      值

最  大
噪  声 (mVpk-pk)

Attenuation characteristics
(%/ms)

Low frequency  Bandwidth
(Hz)

50Hz时  Phase lead (deg)

High-frequency bandwidth
(MHz)

电 流
(KA)

di/dt
(KA/µs)

Cable length100
(mm)

Cable length200
(mm)

CWT03LF

100.0

0.06

0.4

16.0

10.2

11.0

18.6

5.0

4.0

CWT06LF

50.0

0.12

0.8

16.0

5.1

5.6

9.3

12.0

7.5

CWT1 LF

20.0

0.3

2.0

15.0

2.2

2.3

4.0

12.0

7.5

CWT3 LF

10.0

0.6

4.0

15.0

1.0

1.1

1.7

12.0

7.5

CWT6 LF

5.0

1.2

8.0

15.0

0.5

0.55

0.85

12.0

7.5

CWT15LF

2.0

3.0

14.0

15.0

0.2

0.22

0.35

12.0

7.5

CWT30LF

1.0

6.0

14.0

15.0

0.1

0.11

0.18

12.0

7.5

CWT60LF

0.5

12.0

14.0

15.0

0.05

0.055

0.09

12.0

7.5

CWT150LF

0.2

30.0

14.0

15.0

0.02

0.022

0.035

12.0

7.5

CWT300LF

0.1

60.0

14.0

15.0

0.01

0.011

0.018

12.0

7.5

CWT600LF

0.05

120.0

14.0

10.0

0.007

0.008

0.012

12.0

7.5

*1 Maximum noise (mVpk-pk)     Distributed around the low-frequency bandwidth (-3dB)
*2 High-frequency bandwidth (Hz)       The high-frequency bandwidth depends on the length of the loop section; maintain the FH value of other contact loops of PEM

Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)

Inquiry Type: Message