Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
Cybertek CTA200 (200A/500kHz) High-Precision Current Transformer CTA Series Cybertek

Cybertek CTA200 (200A/500kHz) High-Precision Current Transformer CTA Series Cybertek

Model:CTA200      Country of Origin:China

Category:Fluxgate current transformer

Overview:
CTA200 (200A/500kHz)

Current measurement range ±200A

Accuracy up to 0.03%


Features
Specifications
Application Notes
Functions & Configuration

The CTA series is an ultra-high-precision current transformer capable of measuring both DC and AC simultaneously. Current range from 60A to 1000A; accuracy up to 0.03%; bandwidth up to 800kHz. Using fluxgate technology to achieve high-precision measurement, superior linearity, extremely low DC offset, low temperature drift, low insertion loss, strong anti-interference performance, low noise and other characteristics, it is very suitable for high-precision and high-stability current measurement, and is widely used in industrial, medical, laboratory and other occasions.


The CTA series current transformers include CTA60 (60A), CTA200 (200A), CTA700 (700A), CTA1000 (1000A). The measurement aperture of CTA60 and CTA200 is 26mm; the measurement aperture of CTA700 and CTA1000 is 30mm. Standard 9 pin D-Sub male interface; working status LED indication function; easy to use, safe and reliable.

Specifications

Measurement conditions: Temperature: 25℃; Supply voltage: ±Uc =±15V


型  号

CTA200

Maximum measured continuous DC currentIPN DC

200A

Maximum measured continuous RMS currentIPN

141A

Measurement current rangeIPM

±200A

Current transfer ratio KN

1:1000

Output currentIS

±200mA

Accuracy(DC,50/60HzSine wave)

≤±(Reading0.03%+30uA)

Bandwidth(±3dB) BW

500kHz

Load resistanceRM(Across the entire measurement current, temperature, and operating voltage range)

RM min

RM max

0

30Ω

Reference figure1

Maximum overload capacity @ single pulse100ms

±1000A

Supply voltage

±15V(±5%)

Supply current

≤80mA+IS

Rated operating voltage
RMS(IEC61010-1)

Basic insulation

2000V

Beinforced insulation

600V

Maximum measurement aperture

26mm

Secondary interface

D-Sub-9Pin

Mounting screws and tightening torque

M4Stainless steel screws*4;2.8Nm
M5Stainless steel screws*2;3.7Nm

image.png 

 

 

 


Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)

Inquiry Type: Message