Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
Cybertek P1300 (1300Vpk/50MHz) Zhiyong High Voltage Differential Probe (Economy Model)

Cybertek P1300 (1300Vpk/50MHz) Zhiyong High Voltage Differential Probe (Economy Model)

Model:P1300      Country of Origin:China

Category:High-voltage differential probe

Overview:

Bandwidth (-3dB) DC to 50MHz

Rise time ≤7ns

Accuracy ±2%

Range selection (attenuation ratio) 50X/500X


Features
Specifications
Application Notes
Functions & Configuration

P1300 High-Voltage Differential Probe is a high-voltage differential probe with floating measurement capability.

Its bandwidth reaches 50MHz, meeting the needs of most test systems;

Two ranges are available for selection, and its differential measurement voltage range meets the requirements of most test circuits;

It features an overload alarm function;

The probe is equipped with a standard BNC output interface and can be used with oscilloscopes from any manufacturer.

The probe has good common-mode noise rejection capability, and the input end has high input impedance and low capacitance, enabling accurate and high-speed measurement of differential voltage signals.

It can be widely used in the R&D, debugging, or maintenance of switching power supplies, inverters, electronic ballasts, inverter home appliances, and other electrical power devices.

Model

P1300

Bandwidth(-3dB)

50MHz

Rise time

≤7ns

Accuracy

±2%

Range selection (attenuation ratio)

50X/500X

Maximum differential measurement voltage
(DC + Peak AC)

50X

±130V

500X

±1300V

Common-mode voltage (DC + Peak AC)

±1300V

Maximum differential mode voltage vs. frequency curve

Refer to Figure 1 below

Maximum input-to-ground voltage (Vrms)

600V CATIII 1000V CATII

Input impedance

Single-ended to ground

5MΩ

Two Input Terminals

10MΩ

Input capacitance

Single-ended to ground

<4pF

Two Input Terminals

<2pF

CMRR

DC

>80dB

100kHz

>60dB

1MHz

>50dB

Noise (Vrms)

50X

<50mV

500X

<300mV

Overload indication voltage threshold

50X

≥140V

500X

≥1400V

Delay time

Probe main unit

Approx. 10ns

BNC output cable (1 meter)

Approx. 5ns

Overload Indicator (Red LED)

有

Terminal load requirements

≥100kΩ

Power adapter

DC 12V/1.2A