Quick Contact>

Hotline

0731-85260926 18665876229

中文
Power Transistor Curve Tracer Semiconductor Parameter Analyzer SMU Source Measure Unit Dynamic Parameter Test System CV Parameter Tester Gate Charge (Qg) Tester WAT Wafer Acceptance Test System TLP Transmission Line Pulse EMMI Low-Light Infrared Fault Localization HCI/BTI/TDDB/EM effects Femtoammeter/Electrometer/High Resistance Meter High and low temperature electrical performance simulation H3TRx Customizable System Integration Software
Standard Manual Probe Station Portable Desktop Probe Station Semi-automatic probe station RF/Microwave Probe Station High/Low Temperature Probe Station Vacuum cryogenic probe station system Wafer electrical parameter test system Strong Magnetic - Hall Probe Station Custom Precision Probe Card High/Low Temperature Chuck System (Taiko) Magnetic Probe Holder CCD Microscope Test cables and adapter fixtures Shielded Box and Vibration Isolation Table Probes and other accessories
B-H Analyzer Magnetic Loss Power Tester Impedance Analyzer DC Bias High-Frequency LCR Meter Vector Network Analyzer VNA Frequency Response Analyzer Milliohm Meter / Battery Internal Resistance Tester
Rapid Temperature Change Thermal Flow Meter Device High/Low Temperature Platform Thermalplate Device junction temperature simulator Tj
12-bit high-definition digital oscilloscope Optically Isolated Oscilloscope System Basic Digital Oscilloscope Signal generator Digital Multimeter DMM Spectrum Analyzer Frequency counter Infrared thermal imager
Optically isolated voltage probe Optically Isolated Current Probe Dynamic On-Resistance Rds(on)dynamic Oscilloscope voltage probe High-voltage differential probe Fluxgate current transformer AC/DC Current Probe Non-inductive coaxial shunt Communication Interfaces and Cables Dedicated fixture Software
Multi-channel data acquisition instrument Data Acquisition and Playback Power Analyzer
Digital Phase-Locked Loop Amplifier Ultra-Low Noise Preamplifier Precision Current Amplifier Precision Differential Amplifier Precision Filter Light chopper Precision Low-Noise DC Power Supply
Programmable DC Power Supply DC Electronic Load Precision Bipolar Power Amplifier Bipolar simulation power supply
Safety Tester (ACI/DCI/IR/GB) High-voltage meter HV meter
Standard or calibration source meter Standard current and voltage meters

Products

Product information

Products
IWATSU SY-8232/SY8258 Iwasaki AC BH Saturation BS and Loss Analyzer for Soft Magnetic Materials - Discontinued

IWATSU SY-8232/SY8258 Iwasaki AC BH Saturation BS and Loss Analyzer for Soft Magnetic Materials - Discontinued

Model:SY-8232/8258      Country of Origin:Japan

Category:B-H Analyzer

Overview:

Note: This model has been discontinued. The specification models are SY-8218 (high frequency 10 MHz) and SY-8219 (1 MHz)


The SY-8232 high-frequency B-H analyzer is the flagship of IWATSU’s line of B-H analyzers. It has a high-frequency B-H curve tracing capability over an ultrawide-range measurement frequency from 10 Hz (optionally 1 Hz) to 10 MHz. 

Features
Specifications
Application Notes
Functions & Configuration
Features:

Ultrawide measurement frequency


bandwidth

-The frequency range for measurement is exceptionally wide, from 10 Hz (optionally 1 Hz) to 10 MHz.


Desktop size, all-in-one construction
-A compact design incorporating an oscillation circuit, power amplifier circuit, high-speed digitizer, operation control circuit and printer. Magnetic head material can be directly measured by the built-in power amplifier (25 VA) for excitation. (An optional external power
amplifier can also be used.)


Continuous measurement function and an extensive selection of other measuring functions
-Continuous measurement with up to 12 steps, and various measurements including a B-H curve, core loss curve, µ- characteristics and L-characteristics, are available.


High-speed, high-precision measurement
-High-speed measurement in approx. 3 seconds can be performed. In addition, an FFT arithmetic circuit permits automatic compensation and calibration of frequency characteristics, enabling high-precision
measurements.


Printer provided as standard (built-in)
-Measurement results can be printed out immediately. Convenient for data sorting.


GP-IB interface provided as standard
-An automated measurement system in combination with a PC can be configured.


Easy-to-view 9-inch color CRT display


Easy operation with pop-up menu system
-Pop-up menus are displayed on the CRT to facilitate operation.
-Results are displayed as graphs or lists.

Enhanced measurement efficiency with a wide range of options
-Options include an external power amplifier and sample connection pod for various use.


 Description

The SY-8232 high-frequency B-H analyzer is the flagship of IWATSU’s line of B-H analyzers. 

It has a high-frequency B-H curve tracing capability over an ultrawide-range measurement frequency from 10 Hz (optionally 1 Hz) to 10 MHz. 

The SY-8232’s compact design makes it ideal for desktop use. It incorporates features required for measuring high-frequency magnetic characteristics, including an oscillation circuit, power amplifier circuit, high-speed digitizer, operation control circuit and a printer. 

The built-in 25 VA power amplifier allows direct measurement of small specimens such as magnetic heads, while use of an external power amplifier enables measurement of large amplitude characteristics and saturation characteristics of power ferrite or ultrathin amorphous materials. The lower limit frequency is as low as 10 Hz (optionally 1 Hz), permitting the measurement of near DC magnetic characteristics of soft magnetic materials. As the analyzer allows both near DC and AC, the measurements of coercive force (Hc) related to magnetic wall production, migration and extinction can be more effective and research and testing in materials development can be performed more quickly.


Specifications


Measurement modes

Core loss measurement: Frequency (f) or maximum magnetic flux density (Bm) can be varied.
B-H curve measurement: Frequency (f) or maximum magnetic field (Hm) can be varied.
Permeability measurement: Frequency (f) can be varied.

 

Measured items

Core loss measurement: Max. magnetic flux density (Bm), residual magnetic flux density (Br), max. magnetic field (Hm), coercive force (Hc), core loss (Pc, Pcv, Pcm), phase (q), amplitude permeability (µa), hysteresis loss (Ph), eddy-current loss (Pe).
B-H curve measurement: Max. magnetic flux density (Bm), residual magnetic flux density (Br), max. magnetic field (Hm), coercive force (Hc), core loss (Pc, Pcv, Pcm), phase (q), amplitude permeability (µa), differential permeability (µdiff), square ratio (Br/Bm), total magnetic flux change (2f m)
Permeability measurement: Max. magnetic flux density (Bm), max. magnetic field (Hm), core loss (Pc), phase (q), amplitude permeability (µa), inductance (L), complex permeability (µ’, µ”).

 

Operation modes

Single: One measurement step with one operation.
Continuous: Up to 12-step preset schedules (frequencies or amplitudes) can be measured continuously with one operation.

 

Set frequency

10 Hz (optionally 1 Hz) to 10 MHz, 2 digits effective
Accuracy: ±0.1% for the set value.

 

Measurement time

Approx. 3 sec./step (when the measured frequency is 1 kHz or more)

 

 

Oscillating section

Oscillation frequency: 10 Hz to 10 MHz, sine wave
Output voltage/resistance: 0 to ±2.5 V/50 ½
Built-in excitation control in 3 steps of approximate value, asymptotic and demagnetization.

 

Excitation section

Output voltage ±50 V max., output current ±1 A max. ( 1.1 kHz) or ±4 A max. (10 Hz (optionally 1 Hz) to 1 kHz).
Output impedance 1 ½ + 0.1 µH, output power 25 VA.

 

Detection section (standard)

Excitation current detection
System: Voltage drop across two ends of non-inductive resistance.
Detection sensitivity: ±50 mA to ±5 A (1-2-5 steps)
Frequency bandwidth: DC to 100 MHz


Magnetic flux detection
System: Detection of voltage (induced voltage) across two ends of detection coil.
Detection sensitivity: ±50 mA to ±50 V (1-2-5 steps)
Frequency bandwidth: DC to 100 MHz

 

Storage section

Sampling rate: 512 times the set frequency (synchronized with the built-in oscillator).
Resolution: 16 bits

 

Display section

System: 9-inch color CRT
Contents: Measuring condition, characteristic values, B-H curve, characteristic graphs

 

Printer (Built-in)

Heat-sensitive dot line system. Paper width approx. 112 mm, printing time no more than approx. 5 sec.

 

External interface

GP-IB interface

 

Power supply

100 V AC (90 ~ 132 V) or 200 V AC (180 – 250 V) models.Approx. 800 W (100 V AC)

 

Dimensions & weight

Main unit: Approx. 420W x 350H x 520L mm (excluding the pod), approx. 34 kg (SY-8232 mainframe + SY-301 measurement unit)

 

Environment

Operating temperatures +5°C to +35°C (+10°C to +30°C when the printer is used)

Performance guaranteed temperatures

+18°C to +28°C

Provided accessories

SY-921 measurement pod (1 set), power cords (2), connection cables (1 set), estimation samples (1 set), adapters for calibration (1 set), Thermal paper (2 rolls), fuses (4), instruction manual (1), dust cover (1), accessory case (1).

 

 


 Models, Options, & Accessories


Model

Description

List Price

Sale Price

SY-8232

Please call or email us for pricing and availability.

Model

Accessories

List Price

Sale Price

SY-922

Please call or email us for pricing and availability.

SY-931

Please call or email us for pricing and availability.

SY-927

Please call or email us for pricing and availability.

SY-928

Please call or email us for pricing and availability.

SY-937

Please call or email us for pricing and availability.

SY-924

Please call or email us for pricing and availability.



Looking for more sales, technical and solutions information?

Contact Us >

Leave a Message

Hotline

0731-8526092618665876229

We will get back to you as soon as possible. Thank you!
(Jectronic handles your information with care. By submitting, you confirm that you have read and agree to the personal information transfer statement of this website.)

Inquiry Type: Message